Reference: 68457

A wood gasification boiler with a capacious loading chamber for large logs of wood.

Wood gasifying boiler ATTACK DPX

Reference: 68457

A wood gasification boiler with a capacious loading chamber for large logs of wood.

Price: zł9,519.00
Najniższa cena z ostatnich 30 dni: zł9,519.00
Power output [ kW ]
Sterowanie
Last items in stock
Bezpieczne płatności

Testowy opis płatności

Szybka dostawa

Kolejny testowy opsi

30 dniowe zwroty

Zwroty do 30 dniu bezpłatne

Kup teraz, a otrzymasz w Thursday, 26 November!
  • Na drugi i kolejny produkt

    Jakiś testowy opis

  • Na trzeci i kolejny produkt

    Jakiś testowy opis

Kocioł zgazowujący drewno ATTACK DPX
Price: zł9,519.00
Najniższa cena z ostatnich 30 dni: zł9,519.00
Notify me of availability

Description

Wood Gasifying Boiler ATTACK DPX

The ATTACK DPX boiler is a wood-fired boiler from the 6000 series. It is adapted for burning wood, which makes it very convenient to use. The gasifying boiler is environmentally friendly, offering high-quality construction and excellent efficiency. The larger fuel chamber saves time needed for continuous fuel replenishment. Heating with the DPX boiler provides high comfort and long lifespan. This boiler is a versatile solution that ensures efficient biomass combustion, resulting in high boiler efficiency. There is an option to choose a boiler version with the flap opening on the right or left side. The DPX15 version does not have flue gas turbulators, which means the boiler needs to be cleaned manually.

Warranty for ATTACK boilers:

  • 24 months
  • 36 months if installed with a buffer tank and Laddomat charging unit

Long Burning Time

With full utilization of the loading chamber, the fuel in the boiler will burn continuously for 8-12 hours, depending on the boiler's power. Pieces of wood with a length of 1.2 meters only need to be cut in half once because of the above-standard loading chamber length, allowing for the use of significantly larger pieces of wood.

Attack

Automatic Flue Damper

The DPX boiler features an automatic flue damper for ignition and adding wood. The damper ensures direct exhaust gas extraction from the loading chamber to the chimney and facilitates easier boiler ignition. Opening the loading doors opens the damper, which automatically closes after they are shut, eliminating the need for manual operation.

Wood Boiler and Its Quality of Manufacture

The DPX gasifying boiler, like all ATTACK products, is manufactured using high-quality materials and appropriate technological solutions, such as 6 mm boiler steel, movable turbulators, and fireproof/heat-resistant fittings up to 1350 °C. All of this guarantees the high quality of the boiler's manufacture.

Attack burner

Higher Boiler Power and Control Options

The DPX wood gasifying boiler is equipped with Profi regulation. Boiler control is very simple and intuitive, with each adjustment having different properties. Of course, the boiler includes automatic fuel extinguishing, automatic cleaning, control of heating pumps and charging the accumulation tank. To achieve higher boiler power, we recommend purchasing an accumulation tank together with the Laddomat mixing device.

Attack burner

Profi Boiler Regulation

If there is a need to control a larger number of devices, it is worth considering a boiler with Profi control. Profi-type control utilizes a more precise PID regulator, allowing for more efficient parameter regulation. This results in more precise and smooth regulation of fan speeds, and thus better control of flue gas temperature, which affects the final boiler efficiency. In addition to PID regulation, Fuzzy Logic technology contributes to improved combustion efficiency. It utilizes sensors to monitor combustion and adjust the process in real time for performance optimization. The PROFI regulation system allows for the operation of complex heating systems. It is possible to control the charging pump of the accumulation tank, domestic hot water, or the heating circulation pump. The presented PROFI system also operates the accumulation tank and prevents its discharge by shutting down the boiler when there is no fuel in it. The PROFI regulation is very simple and user-friendly. The display shows all necessary operating information (boiler temperature, flue gas temperature, accumulation tank temperature) and the current status of individual components (fan operation, domestic hot water/accumulation tank charging pump operation, circulation pump operation).

Profi Regulation Features

  • Suitable for daily heating
  • PID regulator - more precise and smooth regulation of fan speed
  • Fuzzy Logic control sensors
  • Controls 2 pumps (heating circulation pump + accumulation tank charging pump or domestic hot water)
  • For systems with an accumulation tank - built-in logic for tank charging and protection against discharge
  • Easy operation and display showing current operating information (boiler temperature, flue gas temperature, accumulation tank temperature)
  • Monitoring of parameters (fan operation, domestic hot water/accumulation tank charging pump operation, circulation pump operation)
  • Control of the circulation pump using a thermostat
  • Automatic boiler shutdown after fuel burning
  • Manual adjustment of primary and secondary air
Attack burner

Boiler Structure and Cross-Section

Attack burner

Technical Data

Parameter DPX15 DPX25 DPX30 DPX35 DPX40 DPX45 DPX80 DPX100
Nominal Power (STANDARD version) [kW] 15 25 30 35 40 45 80 100
Power Range (PROFI version) [kW] 7.5-15 12.5-25 15-30 17.5-35 20-40 22.5-45 32-80 40-100
Heat Exchanger Surface Area [m2] 1.98 2.52 2.78 3.03 5.60
Fuel Loading Chamber Volume [dm3] 82 125 158 190 440
Loading Door Dimensions [mm] 235×445 292×542
Required Chimney Draft [Pa] 23 35
Max. Water Pressure in Boiler [kPa] 250
Water Side Pressure Loss (T 10K) [kPa] 1.9 2.3 4.4 6.6 2.1
Water Side Pressure Loss (T 20K) [kPa] 0.6 0.7 1 1.8 0.55
Boiler Weight [kg] 370 430 460 490 800
Flue Connection [mm] 150 200
Height [mm] 1240 1575
Width [mm] 700 915
Depth [mm] 840 1240 1340 1440 1890
Loading Chamber Length [mm] 400 590 690 790 1100
Protection Class [-] 21
Electricity Consumption [W] 32 38 48 54 78 90
Boiler Efficiency [%] 91.3 90.4 90.1 90.2 86.5 87
Boiler Class [-] 5
Flue Gas Temperature at Nominal Power [°C] 160 165 170 180 170 180 204 205
Flue Gas Flow Rate at Nominal Power [kg/s] 0.014 0.018 0.020 0.022 0.025 0.028 0.045 0.050
Max. Noise Level [dB] 65
Fuel [-] Dry wood with a calorific value of 15-17 MJ/kg, moisture content min. 12% - max. 20%, Φ 80-150 mm
Average Wood Consumption [kg/h] 3.9 6.5 7.8 9.1 10.4 11.75 21.5 26.8
Fuel Consumption per Season [-] 1 kW = 0.9 m3
Max. Wood Length [mm] 350 550 650 750 1000
Operating Hours at Maximum Power [hours] 3
Boiler Water Volume [L] 80 100 110 128 250
Required Accumulation Tank Capacity [L] 800 - 1500 1000 - 2500
Electrical Power Supply [V/Hz] ~230/50
Range of Heated Water Temperature Regulation [°C] 65-90

Product Details

Brand
Reference
68457
In stock
3 Items
Condition
New
Distance from flooring to exhaust gas pipe base [ mm ]
1407

Comments

4 other products in the same category

Viewed products

1000+

Produktów w ofercie

24h

Szybka dostawa

5/5

Wysoka jakość obsługi

5000+

Zadowolonych klientów

Loading...