The METAL-FACH SMART MULTI is a central heating boiler designed to burn two types of fuel: hard coal in small-grain form and wood pellets. Coal is the primary fuel, while wood pellets are intended as an alternative fuel.

Coal and Pellet Boiler Metal-Fach SMART MULTI 15 - 30 kW

The METAL-FACH SMART MULTI is a central heating boiler designed to burn two types of fuel: hard coal in small-grain form and wood pellets. Coal is the primary fuel, while wood pellets are intended as an alternative fuel.

  • New
  • Out-of-Stock
Price: GBP2,759.02
Power output [ kW ]
Boiler feeder

Notify me of availability

Out-of-Stock
Coal and Pellet Boiler Metal-Fach SMART MULTI 15 - 30 kW
Price: GBP2,759.02
Notify me of availability

Description

METAL-FACH SMART MULTI Boiler – for Coal and Wood Pellets

The METAL-FACH SMART MULTI is a central heating boiler designed to burn two types of fuel: hard coal in small-grain form and wood pellets. Coal is the primary fuel, while wood pellets are intended as an alternative fuel. The boiler features an automatic fuel feeder, an Ekoenergia II cast-iron burner with an automatic igniter, a PLATINUM controller and a horizontal, shelf-type heat exchanger.

The SMART MULTI range comprises four nominal output versions: 15, 20, 25 and 30 kW. Individual models differ in their water capacity, weight and external dimensions, allowing the appropriate version to be selected according to the design requirements of the heating system.

According to the manufacturer, the boilers meet Class 5 and Ecodesign requirements. The declared energy efficiency class is A+ when burning wood pellets and B when burning coal. The manufacturer also offers the possibility of extending the standard two-year warranty to five years, subject to the conditions specified in the technical documentation.

Two Fuel Types in One Boiler

One of the main features of the METAL-FACH SMART MULTI is its ability to burn hard coal in small-grain form and wood pellets. Coal is the primary fuel, while wood pellets are intended as an additional fuel. This allows two types of fuel to be used in a single appliance in accordance with its intended purpose and technical requirements.

Fuel is transported automatically from the hopper to the burner by a screw feeder. The controller regulates fuel delivery based on sensor readings and the boiler's operating parameters, reducing the need for manual fuel dosing during normal operation.

Only fuels approved by the manufacturer and meeting the requirements specified in the boiler documentation may be used. Modifications to the boiler's construction are prohibited, including the installation of additional grates or other components that would enable fuels to be burned outside the automatic combustion system.

Ekoenergia II Cast-Iron Burner with Automatic Igniter

The SMART MULTI boiler is equipped with an Ekoenergia II cast-iron burner designed to burn hard coal in small-grain form and wood pellets. The integrated automatic igniter automates the fuel ignition process.

The burner works with an automatic screw feeder that transports fuel from the hopper to the combustion zone. The boiler controller manages the operation of the entire system, adjusting its operating parameters according to the settings and signals received from the sensors.

The manufacturer identifies a patented coal ignition system under patent number 002846790-0001. With the appropriate appliance configuration, the burner also enables wood pellets to be burned.

Important: when burning wood pellets, a fire-extinguishing device (firefighter system) must be installed to protect the fuel in the hopper against ignition.

Automatic Fuel Feeder

The screw feeder automatically transports fuel from the hopper to the burner. The controller uses sensor signals and the configured operating parameters to regulate fuel delivery.

Automated fuel feeding reduces the number of manual operating tasks and helps maintain continuous combustion. Correct operation of the system requires suitable fuel, proper controller configuration and compliance with the manufacturer's instructions.

Horizontal, Shelf-Type Heat Exchanger

The METAL-FACH SMART MULTI boiler features a horizontal, shelf-type heat exchanger. Its purpose is to recover heat from the flue gases and transfer it to the heating water contained in the boiler's water jacket.

Flue-gas turbulators are installed in the convection channels. These components influence flue-gas flow through the exchanger and support heat transfer between the flue gases and the heat exchange surfaces.

The heat exchanger is designed to be cleaned from the front of the boiler. Front access facilitates maintenance and the removal of deposits that accumulate during operation.

Ceramic Combustion Chamber

The combustion chamber is fitted with ceramic elements designed to help maintain a high temperature in the combustion zone. This supports the burnout of combustion products and the utilisation of the energy contained in the fuel.

Combustion performance also depends on the type and quality of the fuel used, controller settings and the operating conditions of the entire heating system.

Boiler Safety Systems

The SMART MULTI boiler is equipped with safety components that monitor access to selected parts of the appliance and help protect the fuel hopper.

  • Door limit switches: monitor the position of the protected doors. Opening a monitored door stops the burner and other boiler components until the door is closed again.
  • Fuel hopper lid limit switch: monitors the position of the hopper lid and works with the system that stops the appliance when the lid is opened.
  • Pressure equalisation system: provides additional protection intended to reduce the risk of flame travelling back towards the fuel hopper.
  • Fire-extinguishing device (firefighter system): protects the fuel stored in the hopper against ignition. Its installation is required when burning wood pellets.

All safety devices must be used in accordance with the manufacturer's instructions. Removing, bypassing or modifying safety components is prohibited.

Choice of Flue Outlet Position

The SMART MULTI boiler allows the flue outlet to be positioned at the rear or at the top of the appliance. This enables the flue connection to be adapted to the chimney arrangement and the installation conditions in the boiler room.

Before installation, check the dimensions of the selected model, the location of the connections and the requirements for connecting the boiler to the chimney flue. Installation must comply with the boiler's technical documentation and applicable installation requirements.

PLATINUM Controller – Boiler Regulation and Monitoring

The METAL-FACH SMART MULTI boiler is controlled by a PLATINUM controller equipped with a colour touchscreen. The controller allows the boiler's operating parameters to be configured and selected components of the heating system to be managed.

The controller's functions include:

  • control of two mixing circuits, C.O.1 and C.O.2, with a room thermostat,
  • control of the central heating pump, domestic hot water pump, circulation pump and auxiliary pump,
  • real-time clock (RTC) with weekly programming,
  • weather-compensated control,
  • FuzzyLogic and PID control algorithms.

The availability and scope of individual functions depend on the heating system configuration and the additional components installed. Before making connections, verify the technical requirements in the controller documentation.

Remote Control via the Internet

The PLATINUM controller is compatible with the optional ecoNET300 internet module. When installed, the module enables monitoring of the boiler's operating parameters and remote control via the Internet using the ecoNET24 application.

The ecoNET300 module is optional equipment. Before purchasing it, check its availability, compatibility with the selected boiler configuration and the requirements for enabling remote control.

Technical Data – METAL-FACH SMART MULTI

The table below presents the main technical specifications of the individual boiler versions, in accordance with the manufacturer's data.

ParameterSMART MULTI 15SMART MULTI 20SMART MULTI 25SMART MULTI 30
Nominal heat output [kW] 15 20 25 30
Primary fuel Hard coal (small-grain coal), standard 303-5:2021-09
Additional fuel Wood pellets, PN-EN 303-5+A1:2023-05
Water capacity [l] 48 60 71 80
Fuel hopper capacity [l] 200 200 200 200
Fuel hopper capacity [kg] 146 146 146 146
Boiler weight [kg] 380 405 480 522

Note: Additional technical parameters should be verified in the technical and operating documentation (DTR) for the relevant boiler version.

Thermal Efficiency and Particulate Emissions

The manufacturer publishes thermal efficiency and particulate emission data for the individual SMART MULTI models. The values below are reproduced in the format provided in the manufacturer's specifications. Since the order of the fuels corresponding to values separated by a slash is not clearly identified in the source material, the values have not been independently assigned to either fuel type.

ParameterSMART MULTI 15SMART MULTI 20SMART MULTI 25SMART MULTI 30
Seasonal particulate emissions [mg/m³] 23.35 / 34.96 25.58 / 34.21 23.19 / 33.46 23.08 / 32.71
Efficiency at nominal output [%] 90.7 / 90.7 90.7 / 90.6 90.94 / 90.31 91.02 / 90.43
Nominal particulate emissions [mg/m³] 28 / 33.17 20.6 / 32.88 28.9 / 32.6 27.78 / 32.31
Efficiency at minimum output [%] 91.0 / 90.0 90.8 / 90.1 90.72 / 90.24 90.88 / 90.35
Minimum-output particulate emissions [mg/m³] 22.5 / 35.27 21.26 / 34.44 22.18 / 33.61 22.25 / 32.78

Boiler Class, Ecodesign and Subsidy Information

According to the manufacturer, all SMART MULTI versions meet Class 5 and Ecodesign requirements. The declared energy efficiency class is A+ when burning wood pellets and B when burning coal.

ParameterSMART MULTI 15SMART MULTI 20SMART MULTI 25SMART MULTI 30
ZUM List identifier – – – –
Clean Air Programme eligibility No No No No
Ecodesign Yes Yes Yes Yes
Boiler class 5 5 5 5
Energy efficiency class – wood pellets A+ A+ A+ A+
Energy efficiency class – coal B B B B

According to the information published by the manufacturer, the SMART MULTI boilers are not listed in the ZUM List and are not eligible for the Polish Clean Air Programme. These details should be verified before purchase, as subsidy rules and approved appliance lists may change.

Dimensions of the SMART MULTI Boiler

The boiler's external dimensions must be considered when planning the installation location, positioning the connections and allowing sufficient service access. The values below correspond to the manufacturer's specifications; the letter designations refer to the appliance's technical drawing.

Dimensional Drawing

Technical drawing showing boiler dimensions
Dimension designationSMART MULTI 15SMART MULTI 20SMART MULTI 25SMART MULTI 30
A [mm] 1135 1135 1185 1300
B1 [mm] 535 535 585 585
B2 [mm] 580 580 580 580
C1 [mm] 1340 1400 1400 1485
C2 [mm] 1240 1300 1300 1395
D1 [mm] 590 660 750 750
D2 [mm] 560 630 720 720
E [mm] 610 630 630 630
F1 [mm] 435 505 595 580
F1' [mm] 1100 1155 1155 1190
F2 [mm] 1100 1155 1155 1255
F3 [mm] 140 140 140 140
F4 [mm] 115 115 115 115
G1 [mm] 160 160 160 180
G1' [mm] 160 160 160 180
G2 – manufacturer's value 1 1/2 1 1/2 1 1/2 1 1/2
G3 – manufacturer's value 1 1/2 1 1/2 1 1/2 1 1/2
G4 – manufacturer's value 3/4 3/4 3/4 3/4
H [mm] 30 30 30 30

Note: Dimensions G2, G3 and G4 are retained in the format provided by the manufacturer. Their meaning should be verified against the dimensional drawing and the technical documentation before making connections.

When planning the boiler room, allow sufficient space not only for the appliance itself but also for opening the doors, cleaning the heat exchanger, refilling the fuel hopper and carrying out maintenance. The final installation arrangement must comply with the technical documentation and applicable installation requirements.

Warranty and Technical Documentation

The manufacturer specifies a standard warranty period of two years, with the possibility of extending it to five years subject to the conditions set out in the technical documentation.

Before installation and commissioning, read the SMART MULTI boiler operating instructions and the PLATINUM controller documentation. The manufacturer also provides certificates for the individual output versions, energy labels and product information sheets.

Installation, commissioning, cleaning and maintenance must be carried out in accordance with the manufacturer's instructions. Unauthorised modifications to the appliance may result in loss of warranty coverage.

Frequently Asked Question

Can the METAL-FACH SMART MULTI boiler burn both coal and wood pellets?

Yes. The boiler is designed to burn hard coal in small-grain form as the primary fuel and wood pellets as an additional fuel. It features an Ekoenergia II cast-iron burner with an automatic igniter and an automatic fuel feeder. When burning wood pellets, a fire-extinguishing device must be installed to protect the fuel stored in the hopper against ignition.

Product Details

Brand
Condition
New

Comments

Viewed products

1000+

Produktów w ofercie

24h

Szybka dostawa

5/5

Wysoka jakość obsługi

5000+

Zadowolonych klientów

Loading...
Back to top