The PELL-STAR boiler is a combination of modern technology, reliability, and user comfort. It is the perfect solution for those who value efficiency, safety, and minimal involvement in the daily operation of heating systems.
- New
- Out-of-Stock
Description
Universal Hopper for PELL-STAR Boiler
Thanks to its thoughtful design, the hopper can be freely positioned relative to the boiler. This is an ideal solution for installations in hard-to-reach areas, ensuring complete flexibility during setup.
Smart Boiler Controller
The advanced controller enables remote operation and management of multiple heating circuits. It supports mixing valves with actuators, allowing precise customization of the heating system to the user's individual needs.
Compact and Efficient Heat Exchanger
The vertical design of the heat exchanger provides exceptional thermal efficiency while maintaining compact dimensions. This is the perfect combination of space-saving and high performance.
VENMA "COMFORT" Modular Burner
This technologically advanced burner with an automatic igniter offers a range of innovative features:
- Automatic Operation: Fully automated processes for ignition, maintenance, extinguishing, and cleaning minimize manual intervention.
- Durable Components: Robust construction ensures reliability and longevity, even under demanding conditions.
- Top-Level Safety: Flame and temperature sensors protect the burner from overheating, ensuring safe operation.
- Continuous Operation: Automatic cleaning during operation and quick restart after a power outage eliminate system downtime.
Why Choose This Heating System?
This system combines modern technologies, reliability, and user comfort. It is the ideal solution for those who value efficiency, safety, and minimal involvement in the daily operation of heating devices.

| Parameter | Unit | Model | PELL-STAR 18 |
|---|---|---|---|
| Dimensions | |||
| D | [mm] | ∅ | 159 |
| L1 | [mm] | 1249 | |
| L | [mm] | 877 | |
| H | [mm] | 1346 | |
| H1 | [mm] | 1033 | |
| H2 | [mm] | 845 | |
| H3 | [mm] | 832 | |
| H4 | [mm] | 152 | |
| S | [mm] | 490 | |
| S1 | [mm] | 540 | |
| S2 | [mm] | 1179 | |
| Fuel and Performance | |||
| Primary Fuel | — | Wood pellets (see: Section 2.5) | |
| Nominal Thermal Power | [kW] | 18 | |
| Thermal Power Range* | [kW] | 5.4 – 18 | |
| Heated Space Volume** | [m³] | 800 | |
| Heated Space Area** | [m²] | 320 | |
| Hopper Capacity | [L] | 300 | |
| Boiler Water Capacity | [L] | 95 | |
| Maximum Operating Pressure | [bar] | 2 | |
| Required Minimum Chimney Draft*** | [mBar] | 0.2 | |
| Flue Gas Temperature at Nominal Power | [°C] | 112 | |
| At Minimum Power | [°C] | 78 | |
| Flue Gas Mass Flow at Nominal Power | [g/s] | 3.139 | |
| At Minimum Power | [g/s] | 1.194 | |
| Fuel Consumption at Nominal Power | [kg/h] | 4 | |
| Water Supply Temperature | [°C] | min. 57 / max. 80 | |
| Minimum Boiler Return Temperature | [°C] | 55 | |
| Electrical and Noise Parameters | |||
| Boiler Power Supply | — | 230 V – 50 Hz / 400 V – 50 Hz | |
| Electrical Power | [W] | 288.2 | |
| Standby Power | [W] | 4.6 | |
| Power Consumption at 30% Load | [W] | 58 | |
| Power Consumption at 100% Load | [W] | 30 | |
| Noise | [dB] | < 65 | |
| Boiler Weight Without Water | [kg] | 340 | |
| Supply and Return Connection Diameter | — | GZ 1 1/2” | |
| Efficiency and Certification | |||
| Thermal Efficiency According to CSN EN 303-5+A1:2023 (Nominal – Minimum Power) | [%] | 91.36 – 90.36 | |
| Energy Class | [%] | A+ | |
| Controller / Fan | — | YES / YES | |
| Boiler Operation in Overpressure [+] / Underpressure [–] | — | [+] | |
| Warranty | — | 10 years for weld tightness, 60 months for exchanger tightness, 24 months for components | |
| Heat Exchanger Material | — | P265GH Steel PN-EN 10028 | |
| Temperature Settings Range on Controller | [°C] | 45 – 80 | |
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent