The HPH Hygienic series buffer tanks are designed for efficient and hygienic preparation of domestic hot water in flow mode.
- New
- Out-of-Stock
Description
Versions of KHT HPH Hygienic tanks:
KHT HPh-10-GP-PS - without additional coil
KHT HPh-11-GP-PS - with additional carbon steel coil
KHT HPh-12-GP-PS - with 2 additional carbon steel coils
KHT HPh-20-GP-PS - with additional stainless steel coil
HPH Hygienic — hygienic flow buffer tanks
The buffer tanks of the HPH Hygienic series have been designed for efficient and hygienic domestic hot water preparation in flow mode. The product uses the accumulated thermal energy from the heating system and transfers it directly to the domestic water through an integrated large-surface heat exchanger. As a result, the water is heated quickly and only at the moment of consumption — minimizing energy losses and making the solution particularly advantageous in low-temperature heating systems (e.g., heat pumps).
Hygienic water preparation
The heat exchanger is made of corrugated stainless steel tube AISI-316L, a material with high corrosion resistance and hygienic properties. The design of the exchanger limits the risk of bacterial growth (including Legionella), so the tank does not require elevated disinfection temperatures. This allows economical and safe preparation of hot water without the need for periodic heating to very high temperatures.
Applications and functions
HPH Hygienic tanks can work as a separating element of glycol–water circuits, as well as for connecting two heat sources operating at different working pressures. Thanks to their durable, maintenance-free design, the devices do not require annual maintenance or magnesium anode replacement — reducing operating costs compared to traditional enamelled water heaters.
Key advantages
- Flow heating — hot water only at the time of consumption.
- Heat exchanger made of AISI-316L stainless steel — high hygiene and corrosion resistance.
- Reduced Legionella risk — no need for high-temperature disinfection.
- Compatibility with low-temperature installations (e.g., heat pumps).
- Possibility to separate glycol–water circuits and connect sources with different pressures.
- Maintenance-free operation — no annual magnesium anode inspection.
- Longer service life than traditional enamelled heaters.
Typical applications
- Residential and multi-family buildings.
- Public utility and commercial facilities.
- Installations with heat pumps and low-temperature sources.
- Systems requiring separation of the heating medium (glycol–water).
The use of an HPH Hygienic tank is a choice of an energy-efficient solution, safe for users’ health, and requiring minimal maintenance. It is a modern alternative to classic enamelled water heaters.
Technical Data:

| Technical Data | Unit | KHT НРh-11 | |||||||
| 200 | 300 | 400 | 500 | 800 | 1000 | 1500 | 2000 | ||
| Supplier code | - | HPh110200GPPS | HPh110300GPPS | HPh110400GPPS | HPh110500GPPS | HPh110800GPPS | HPh111000GPPS | HPh111500GPPS | HPh112000GPPS |
| Connection nozzles h1 | ”/ mm | 6/4 / 204 | 6/4 / 222 | 6/4 / 227 | 6/4 / 242 | 6/4 / 272 | 6/4 / 277 | 6/4 / 295 | 6/4 / 385 |
| Connection nozzles h2 | ”/ mm | 6/4 / 507 | 6/4 / 525 | 6/4 / 610 | 6/4 / 705 | 6/4 / 655 | 6/4 / 740 | 6/4 / 758 | 6/4 / 848 |
| Connection nozzles h3 | ”/ mm | 6/4 / 811 | 6/4 / 829 | 6/4 / 994 | 6/4 / 1169 | 6/4 / 1039 | 6/4 / 1204 | 6/4 / 1222 | 6/4 / 1312 |
| Connection nozzles h4 | ”/ mm | 6/4 / 1114 | 6/4 / 1132 | 6/4 / 1377 | 6/4 / 1632 | 6/4 / 1422 | 6/4 / 1667 | 6/4 / 1685 | 6/4 / 1775 |
| Temperature sensor sleeve | ” | 1/2 | |||||||
| Connection nozzles/vent h5 | ”/ mm | 5/4 / 1378 | 5/4 / 1414 | 5/4 / 1664 | 5/4 / 1931 | 5/4 / 1736 | 5/4 / 1986 | 5/4 / 2027 | 5/4 / 2206 |
| Return from bottom coil h1 | ”/ mm | 1 / 204 | 1 / 222 | 1 / 227 | 1 / 242 | 5/4 / 272 | 5/4 / 277 | 5/4 / 295 | 5/4 / 385 |
| Supply from bottom coil h6 | ”/ mm | 1 / 604 | 1 / 622 | 1 / 827 | 1 / 842 | 5/4 / 872 | 5/4 / 877 | 5/4 / 1045 | 5/4 / 1135 |
| DHW coil water outlet h4 | ”/ mm | 1 / 1114 | 1 / 1132 | 1 / 1377 | 5/4 / 1632 | 5/4 / 1422 | 5/4 / 1667 | 5/4 / 1685 | 5/4 / 1775 |
| DHW coil cold water inlet h1 | ”/ mm | 1 / 204 | 1 / 222 | 1 / 227 | 5/4 / 242 | 5/4 / 272 | 5/4 / 277 | 5/4 / 295 | 5/4 / 385 |
| Connection nozzles h7 | ”/ mm | 6/4 / 356 | 6/4 / 374 | 6/4 / 419 | 6/4 / 474 | 6/4 / 464 | 6/4 / 509 | 6/4 / 527 | 6/4 / 617 |
| Connection nozzles h8 | ”/ mm | 6/4 / 659 | 6/4 / 677 | 6/4 / 802 | 6/4 / 937 | 6/4 / 847 | 6/4 / 972 | 6/4 / 990 | 6/4 / 1080 |
| Upper electric heater nozzle h9 | ”/ mm | 6/4 / 659 | 6/4 / 677 | 6/4 / 877 | 6/4 / 1037 | 6/4 / 922 | 6/4 / 1047 | 6/4 / 1115 | 6/4 / 1205 |
| Connection nozzles h10 | ”/ mm | 6/4 / 962 | 6/4 / 980 | 6/4 / 1185 | 6/4 / 1400 | 6/4 / 1230 | 6/4 / 1435 | 6/4 / 1453 | 6/4 / 1543 |
| Drain nozzle h11 | ”/ mm | 3/4 / 128 | 3/4 / 146 | 3/4 / 147 | 3/4 / 156 | 3/4 / 191 | 3/4 / 191 | 3/4 / 209 | 3/4 / 299 |
| Lower electric heater nozzle h15 | ”/ mm | 6/4 / 119 | 6/4 / 137 | 6/4 / 137 | 6/4 / 152 | 6/4 / 182 | 6/4 / 182 | 6/4 / 199 | 6/4 / 290 |
| Working pressure of heat exchangers | MPa | 1 | 1 | 1 | 1 | 0.8 | 0.8 | 0.8 | 0.8 |
| Working pressure of DHW coil | MPa | 1 | |||||||
| Surface of bottom heat exchanger | m2 | 1.2 | 1.2 | 1.8 | 1.8 | 3.2 | 3.2 | 4.7 | 4.7 |
| Capacity of bottom heat exchanger | l | 7.4 | 7.4 | 11.2 | 11.2 | 29.5 | 29.5 | 42 | 42 |
| Surface of DHW coil | m² | 3.5 | 3.5 | 4 | 5 | 6 | 7.8 | 8 | 8 |
| Capacity of DHW coil | l | 11 | 11 | 13 | 16 | 23 | 30 | 30.7 | 30.7 |
| Working pressure of tank | MPa | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.3 | 0.3 |
| Height H | mm | 1380 | 1416 | 1666 | 1933 | 1738 | 1988 | 2029 | 2217 |
| Diameter without insulation d | mm | 502 | 603 | 603 | 651 | 790 | 790 | 997 | 1196 |
| Diameter with insulation D | mm | 674 | 775 | 775 | 823 | 962 | 962 | 1169 | 1368 |
| Total capacity | l | 236 | 344 | 419 | 566 | 733 | 850 | 1361 | 2113 |
| Nominal capacity | l | 215 | 323 | 391 | 531 | 675 | 785 | 1279 | 2031 |
| Weight | kg | 70 | 78 | 95 | 109 | 144 | 159 | 233 | 269 |
| Tilt diagonal R | mm | 1409 | 1455 | 1699 | 1968 | 1791 | 2034 | 2099 | 2199 |
| Nominal pipe diameter | DN | 25 | 25 | 25 | 32 | 32 | 32 | 32 | 32 |
| Surface | m² | 3.5 | 3.5 | 4 | 5 | 6 | 7.8 | 8 | 8 |
| Heater length | mm | 500 | 600 | 600 | 650 | 790 | 790 | 995 | 1195 |
| Energy efficiency class | - | B | B | B | B | B | B | C | C |
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent