Description
Defro Spectra for pellet
The boilers meet the energy and emission requirements of class 5 of PN EN 303-5: 2012 standard and have the Ecodesign Certificate.
Standard equipment:
- analog thermometer,
- APC K Slim controller,
- ADAPTIVE CONTROL control,
- PID function,
- igniter,
- palnik pelletowy z funkcją automatycznego czyszczenia,
- fan,
- fuel container,
- tools for boiler,
- ash drawer,
- foot for leveling the boiler,
- mixing valve controller (in the regulator),
- ceramic plate of the furnace chamber,
- STB temperature limiter.
Additional boiler equipment (optional, extra paid):
- Internet module,
- WIFI internet module,
- room regulator DEFRO SPK Lux,
- DEFRO MZ module,
- SPK Lux wireless regulator,
- set for RS wireless communication
- GSM module
- DBV-2 cooling valve.
Dimensions of Spectra boiler

|
Type / Dimensions |
A |
B |
C |
D |
E |
F |
G |
H |
I | J | K1 | K2 | L1 | L2 | M | N |
| 10 | 496 | 1151 | 1376 | 1376 | 1396 | 995 | Ø159 | 630 | 740 | 835 | 158 | 173 | 121 | 391 | 258 | 381 |
| 14 | 496 | 1151 | 1376 | 1376 | 1396 | 995 | Ø159 | 630 | 740 | 835 | 158 | 173 | 121 | 391 | 258 | 381 |
| 20 | 546 | 1201 | 1426 | 1426 | 1446 | 1045 | Ø159 | 630 | 720 | 815 | 158 | 173 | 121 | 441 | 258 | 431 |
| 25 | 546 | 1201 | 1476 | 1476 | 1496 | 1100 | Ø159 | 770 | 860 | 960 | 158 | 173 | 121 | 441 | 258 | 431 |
Pellet burner with automatic cleaning function in standard
5 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler
High thermal efficiency reaching 94% due to increased heat recovery from flue gases
Heat exchanger made of certified high-grade boiler steel
ADAPTIVE CONTROL control - adjustment of boiler operation based on air flow through the heat exchanger
Fuel self-ignition system
Compact dimensions
Ceramic catalysts stabilising combustion process
APC K SLIM ADAPTIVE CONTROL controller servicing three pumps /central heating, domestic hot water, floor/. Control of one mixing valve; preview and change of parameters of the main ONLINE controller - extra payable option
Boiler adapted for installation in the closed system provided that protections were installed in accordance with the operation and maintenance manual of the boiler
The basic components of the Spectra boiler

- steel body with thermal insulation;
- enclosure door;
- upper cleaning doors;
- bottom cleaning doors;
- ash pit door;
- supply connection;
- return connection;
- drain connection;
- flue;
- door of the fuel container;
- lock;
- electronic controller display;
- control module;
- STB temperature limiter;
- main switch;
- pellet burner;
- fuel capacity;
- sliding cover of the fuel capacity;
- fuel feeder with motoreduceror;
- pipe of fuel;
- inspection hole;
- hole flue cleaning
- exhaust sensor mounting socket;
- connection of the exhaust sensor;
- cable outlet of the exhaust sensor;
- cable culvert;
- feet for leveling;
- mounting sleeve of the return water temperature sensor.
|
Model of boiler |
Defro Spectra |
||||
|
Specification / type of boiler |
J.m. | 10 | 14 | 20 | 25 |
|
Nominal power |
kW | 10 | 14 | 20 | 25 |
|
Power range |
kW | 3,0-10 | 4,2-14 | 5,7-20 | 7,2-25 |
|
Boiler weight |
kg | ~340 | ~350 | ~372 | ~467 |
|
The boiler class according to PN-EN 303-5: 2012 |
- | 5 class | |||
|
ECODESIGN |
- | Yes | |||
|
Energy class |
- | A+ | |||
|
Basic fuel |
- | pellets Ø 6-8 mm | |||
|
Fuel class |
- | biogenic fuel - C1 | |||
|
Heating surface |
m2 |
1,5 | 1,8 | 2,3 | 3,0 |
|
Area of heated rooms 1) |
m2 |
to 125 | to 175 | to 240 | to 300 |
|
Disposable fuel charge |
kg | ~68 | ~68 | ~81 | ~112 |
|
Fuel container capacity 2) |
kg | ~141 | ~141 | ~152 | ~199 |
|
Fuel consumption 3) |
kg/h | 2,1 | 2,7 | 4,2 | 5,0 |
|
Optimum thermal efficiency |
% | ~94,7 | |||
|
Max. permissible work pressure 4) |
bar | open system 1,5 /close system 2,5 | |||
|
Required flue gas draught |
Pa | 20 | 23 | 26 | 28 |
|
Water temperature on supply max. |
°C | 65/90 | |||
|
Flue gas temperature for nominal power |
°C | 88,6-117,5 | |||
|
Water capacity of the boiler |
l | 65 | 63 | 71 | 103 |
|
Chimney section |
cmxcm | 14x14 | 14x14 | 14x14 | 15x15 |
|
Chimney section |
Ø mm | 160 | 160 | 160 | 170 |
|
Minimum chimney height |
m | 6 | 6,5 | 7 | 7,5 |
|
The dimensions of the loading opening of the fuel container |
mm | 550x345 | 550x345 | 550x345 | 550x435 |
|
Power consumption work / start-up |
W | 83/383 | |||
|
Power |
V/Hz | ~230V/50Hz | |||
|
Width |
mm | 1151 | 1151 | 1201 | 1201 |
|
Depth |
mm | 835 | 835 | 815 | 960 |
| Height 5) |
mm | 1396 | 1396 | 1446 | 1496 |
|
Height to the bottom edge of the exhaust outlet |
mm | 995 | 995 | 1045 | 1100 |
|
Release socket diameter |
- | ½’’ | |||
|
Diameter of the exhaust gas socket |
mm | 159 | |||
1) Maximum area of heated rooms estimated for unit heat demand q=80 W/m2
2) Fuel tank capacity for pellet bulk density 0,6 kg/dm3.
3) Fuel consumption for pellets with a calorific value of 17,000 ± 300kJ / kg.
4) The condition of installation in a closed system is the use of thermal protection, eg DBV-2.
5) The height of the boiler can be adjusted using the attached feet. The feet have a 38-50mm adjustment range.
Product Details
A+
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent