The Defro Sigma Uni boiler is an automatic and extremely comfortable gutter burner stove designed for eco-pea combustion. The design of the exchanger ensures optimal fuel combustion conditions, high efficiency and low emissions.
Description
Sigma Uni boiler is an automatic and extremely comfortable to operate boiler with a gutter burner adapted to the combustion of eco-pea. It has the highest quality materials used in the production of the burner, which guarantee its long-term operation. Special construction of the exchanger ensures optimal fuel combustion conditions, high efficiency and low emission of pollutants. The boiler has an intuitive and user-friendly controller with a color touch display with an adjustable angle of position.
Sigma Uni meet the energy and emission requirements of class 5 of the PN EN 303-5:2012 standard.
Standarf equipment:
- ADAPTIVE CONTROL,
- controller K1Pv4,
- blower fan (installation on your own),
- burner fuel supply system,
- fuel tank,
- analog thermometer,
- ash drawer,
- Extension of the flue pipe with throttle,
- Exhaust gas turbulences,
- Cylinder cover opening sensor,
- extinguishing system “Firefighter I”,
- silicon,
- maxing valve conreoller (in K1Pv4 regulator),
- levelling feet.
Optional equipment (at extra cost):
- GSM module,
- Internet module,
- Internet module WIFI,
- Igniter,
- Room controler DK LOGIC 100,
- Room controler DEFRO SPK Lux,
- extinguishing system “Firefighter II”,
- module DEFRO MZ,
- NZ version for closed-loop system,
- SPK Lux wireless regulator,
- set for wireless RS communication.
Boiler heat exchanger is made of certified boiler steel (P265GH grade) with a thickness of 6mm.
High thermal effciency of the boiler reaching 88% due to increased heat recovery from outgoing flue gases from the boiler.
ADAPTIVE CONTROL- boiler operation control based on air flow through the exchanger.
Possibility of changing the direction of opening the external door, the fire door does not have such a possibility.
NZ version with reinforced construction and integrated coil for closed-loop operation (additional fee)
Combustion chamber with highly effcient gutter burner.
Fuel feeder screw made entirely from one piece.
Mounted fuel tank cover opening sensor.
Fuel tank pressure compensation system.
Stabilization of the combustion process by means of a ceramic catalytic converter.
System for mechanical cleaning of the heat exchanger (extra charge)
Energy-saving geared motor with autoreversion if the fuel feeder is blocked.
Mounted K1P v4 controller with color touch panel can operate 4 pumps (central heating, hot water, circulation, floor) and mixing valve. As an option is possible to control via GSM or internet.
The manufacturer provides a 5-year warranty on the tightness of the heat exchanger and 2-year warranty on the effcient operatiob of the other components.
Version R- automatic fuel ignition system (option additionally paid).
Automatic, water-based fuel extinguishing system with thermostatic valve "Firewall"
Controller K1Pv4

Function performed by the controller:
- modern control system ADAPTIVE Control with the use of a turbine flow meter ensuring optimal selection of parameters of fan and feeder operation;
- possibility of checking the history of the last twenty alarm states of the boiler;
- option to download the temperature history to an external USB memory stick;
- option to cooperate with the exhaust fan module
- fan and screw feeder control;
- control of the mixing valve actuator as standard;
- Weekly control;
- control of central heating and hot water pumps;
- control of two additional pumps;
- possibility of connecting a room controller with RS or traditional communication;
- option to connect the DEFRO GSM module;
- option of connecting a new version of DEFRO Internet module, which enables remote change of boiler operation parameters (access to user and service menu);
- option to control two additional valves by means of DEFRO MZ modules;
- operation of the geared motor with reversible operation (not applicable to the PZ version);
- large, colour graphic display with touch panel and adjustable tilt angle;
- temperature sensor of central heating, hot water, valve, return, additional, exhaust fumes and outside temperature;
- temperature protection (thermocouple);
- screw temperature sensor (protection);
- High-quality housing.
|
Boiler name |
Defro Sigma UNI |
|||||
| Specification/Type of boiler | S.I. | 16 | 20 | 24 | 36 | 48 |
| Nominal Power | kW | 16 | 20 | 24 | 28 | 38 |
| Power range | kW | 4,8-16 | 6,0-20 | 7,2-24 | 10,8-36 | 14,4-4 |
|
Boiler class wg PN-EN 303-5 |
- | Echaust emissions / effciency - class 5 | ||||
|
ECODESIGN |
- | NIE | ||||
|
Energy effciency class |
- | A+ | ||||
| Temperature of the exhaust gases for nominal power |
[ºC] |
97-119 | ||||
|
Basic fuel |
- | hard coal from the peas range | ||||
|
Heating surface |
m2 |
2,1 | 2,3 | 2,4 | 3,8 | 4,7 |
|
Surface area of heated rooms |
m2 |
do 250 | do 270 | do 290 | do 400 | do 520 |
|
Fuel tank capacity |
kg | ∼165 | ∼165 | ∼165 | ∼191 | ∼266 |
|
Fuel consumption |
kg/h | 2,75 | 2,9 | 3,64 | 4,8 | 6,3 |
|
Flammability |
h | ~60 | ~57 | ~46 | ~40 | ~42 |
|
Optimal thermal effciency |
% | 88,8-88,9% | ||||
|
Max. permissible operating pressure |
bar | open system 1,5 /close system 2,5 | ||||
|
Return water temperature min. |
ºC | 55 | ||||
|
Temperature control range |
ºC | 45 - 80 | ||||
|
Required exhaust gas draught |
Pa | 24 | 26 | 28 | 31 | 34 |
|
Supply water temperature min./max. |
°C | 65/80 | ||||
|
Boiler weight |
kg | 462 | 513 | 529 | 669 | 735 |
|
Boiler water capacity |
l | 97 | 100 | 114 | 160 | 196 |
|
Chimney cross-section |
cmxcm | 14x14 | 16x16 | 16x16 | 18x18 | 22x22 |
|
Chimney cross-section |
Ø mm | 160 | 180 | 180 | 200 | 250 |
|
Minimum height of the chimney |
m | 6 | 7 | 7,5 | 9 | 10 |
|
Width |
mm | 1280 | 1280 | 1280 | 1360 | 1360 |
|
Depth |
mm | 1070 | 1110 | 1110 | 1210 | 1210 |
| Height |
mm | 1430 | 1430 | 1497 | 1557 | 1777 |
|
Diameter of supply and return connections |
mm | 1½’’ | ||||
|
Diameter of the drain pipe |
½’’ | |||||
|
Power supply |
V/Hz | ∼230/50 | ||||
|
Maximum permissible ambient temperature |
ºC | 50 | ||||
|
Coil operating pressure min./max. |
bar | 2/6 | ||||
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent