Stalmark Max II is a modern pellet boiler designed for efficient and economical heating of large-scale facilities. It performs exceptionally well in buildings with an area of up to 2000 m², making it an ideal solution for industrial halls, warehouses, production plants, workshops, and public utility buildings.
Stalmark Max II is a modern pellet boiler designed for efficient and economical heating of large-scale facilities. It performs exceptionally well in buildings with an area of up to 2000 m², making it an ideal solution for industrial halls, warehouses, production plants, workshops, and public utility buildings.
- New
- Out-of-Stock
Description
Stalmark Max II – High-Power Industrial Pellet Boiler
Stalmark Max II is a modern pellet boiler designed for efficient and economical heating of large-scale facilities. It performs exceptionally well in buildings with an area of up to 2000 m², making it an ideal solution for industrial halls, warehouses, production plants, workshops, and public utility buildings.
The boiler has been engineered with a focus on reliability, high thermal efficiency, and stable operation in demanding environments. Thanks to advanced technological solutions, Stalmark Max II ensures efficient pellet combustion, low fuel consumption, and convenient, nearly maintenance-free operation.
Key Advantages of the Stalmark Max II Boiler
- 60-month heat exchanger leak-tightness warranty – robust construction ensuring long service life.
- High combustion efficiency – optimized pellet burning process for lower operating costs.
- Horizontal heat exchanger – made of certified 6 mm steel plate with manual cleaning system.
- Adjustable exhaust fan – can be positioned in various directions depending on installation requirements.
- Stalmark burner – equipped with a self-cleaning grate and automatic ignition function.
- TECH intelligent controller – modern touchscreen control with expansion options for additional accessories.
Standard Equipment
The boiler comes standard with the ST-978T controller, enabling comprehensive heating system management.
Supported Installation Components:
- Central heating pump (C.H.)
- Domestic hot water pump (DHW)
- Valve pump
- 2 additional circulation pumps
- 2 mixing valve actuators
- 2 room thermostats
Optional Additional Equipment
- T-281 – room thermostat
- WiFi RS – internet module for remote boiler control
- T-292 v2 / v3 – advanced room thermostat
- ST i-1 – control module for an additional mixing valve
Stalmark Max II is the ideal solution for investors looking for an efficient, durable, and modern heating source for large commercial and industrial facilities.
Technical Specifications
| Technical Specifications – STALMARK MAX II Boilers | |||
|---|---|---|---|
| Parameter | Unit | 150kW | 300kW |
| Nominal Output | kW | 150 | 300 |
| Output Range | kW | 45-150 | 90-300 |
| Heating Surface Area | m² | 16.7 | 33.9 |
| Heated Building Area* | m² | up to 2000 | up to 3750 |
| Max. Permissible Operating Pressure | MPa | 0.25 | 0.25 |
| Minimum Required Chimney Draft | Pa | 20 | 40 |
| Single Fuel Hopper Capacity | l | 1000 | 1800 |
| Supply Water Temperature [min/max] | °C | 60/80 | 60/80 |
| Minimum Return Water Temperature | °C | 45 | 45 |
| Boiler Weight | kg | 1650 | 3100 |
| Boiler Water Capacity | l | 770 | 1560 |
| Minimum Chimney Height | m | 8 | 8 |
| Boiler Efficiency | % | 92.3 | 32.6 |
| Flue Outlet Diameter | ø / mm | 220 | 300 |
| Supply and Return Connection Diameter (female thread) | in | 2” | 3” |
| Power Supply | V/Hz/A | 230/50/1.4 | 230/50/1.4 |
| Average Power Consumption / Standby Consumption | W | 319/5 | 395/5 |
| Energy Efficiency Class | A+ | A+ | |
| Class 5 | Yes | Yes | |
| Ecodesign | Yes | Yes | |
Dimensions

| Dimensions – STALMARK MAX II Boilers | ||||||||
|---|---|---|---|---|---|---|---|---|
| Model | A [mm] | B [mm] | C [mm] | D [mm] | E [mm] | F [mm] | G [mm] | H [mm] |
| 150kW | 2200 | 1920 | 1580 | 2820 | 900 | 860 | 142 | 139 |
| 300kW | 2655 | 2315 | 2095 | 3270 | 1350 | 1230 | 159 | 130 |