Description
Termo — Tech PRADO is a boiler installed in central heating installations. the production of which is made of 6mm thick boiler plate. This boiler has emission class 5 according to PN EN 303-5:2012 standard. For its proper combustion it is recommended to use pea-coak of 5-25mm granulation. In order to facilitate proper operation of the boiler, its operation is limited to firing up the automatic furnace and, if possible, regular ash removal. The automatic furnace is based on cyclical feeding of small portions of fuel directly to the retort grate and then the blower fan delivers the previously set amount of air to the furnace zone to fully optimize the combustion process. Thanks to this, we are able to achieve high efficiency of the combustion process and reduce the emission of harmful substances to the atmosphere.
The advantage of this type of boilers is:
- Modern design
- Economical and ecological combustion
- Quick and easy to use
- Automatic operation
- Safety in use
- High thermal efficiency
- can be installed in a closed system (12-28kW) after the installation of a cooling coil and BTSzero valve
| Specification | j.m | Data | |||||
| Boiler Type | PRADO | ||||||
| Nominal heat output | [kW] | 12 | 18 | 22 | 25 | 28 | |
| Range of thermal efficiency | [kW] | 3,6-12 | 5,4-18 | 6,6–22 | 7,5-25 | 8,1-28 | |
| Boiler Heating Surface | [m2] | 1,3 | 1,8 | 2,2 | 2,5 | 2,9 | |
| Size of heated surface | [m2] | do 120 | do 180 | do 220 | do 250 | do 280 | |
| Boiler water capacity | [L] | 55 | 62 | 77 | 83 | 88 | |
| Efficiency (brown coal) | [%] | 91,3 | 91,3 | 89,2 | 89,2 | 91,8 | |
| Efficiency (coal) | [%] | 92,2 | 89,6 | 90,7 | 90,67 | 90,1 | |
| Cylinder chamber volume | [dm3] | 132 | 216 | 232 | 260 | 282 | |
| Boiler class | – | 5 | |||||
| Max. operating flow temperature | [°C] | 80 | |||||
| Min. operating temperature flow temperature | [°C] | 55 | |||||
| Maxium working pressure | MPa | 0,25 | |||||
| Test pressure | MPa | 0,5 | |||||
| Required exhaust gas routing | mbar | 0,24 | 0,18 | 0,22 | 0,24 | 0,25 | |
| Flow resistance (10K) | mbar | 2,2-4,0 | |||||
| Chimney opening cross-section min. | [cm2] | 142 | 158 | 215 | 244 | 274 | |
| Minimum height of the chimney | [m] | 6 | 6 | 7 | 7 | 8 | |
| Diameter flue | [mm] | 158 | |||||
| Boiler mass (+/-5%) | [kg] | 325 | 385 | 425 | 444 | 486 | |
| Diameter of discharge and return nozzle | G | 1 1/2 " | |||||
| Diameter of the drain pipe | G | 1/2 " | |||||
| Power supply | V/HZ | ~230V/50Hz/6,3 A | |||||
| Basic dimensions | mm | ||||||
| Depth | [mm] | 1063 | 1063 | 1063 | 1063 | 1127 | |
| Height | [mm] | 1140 | 1345 | 1445 | 1515 | 1515 | |
| Width without tank | [mm] | 465 | 465 | 465 | 465 | 465 | |
| Width with tank | [mm] | 1116 | 1116 | 1116 | 1116 | 1116 | |