Automatic boiler for wood pellets. It is designed for economical and ecological heating with minimal boiler operating requirements. Optional control over the Internet is available.
Description
Wood pellets boiler Viadrus A0C is an automatic boiler available in two sizes - 5 and 7 sections. Its important advantage is extraordinary high efficiency up to 86.9 % and automatic ignition as well.Fuel:
- wooden pellets
Advantages:
- long life of the cast-iron boiler body
- optional huge pellet hopper
- efficiency up to 86.9%
- meets the emission class 4 according to EN 303-5 standards
- optional remote control over the internet
- optionally supplied assembled or unassembled
- reasonable price and high quality
Features of the S.Control
Configuration wizard
- Fast and easy configuration in several steps
- Air and fuel parameters are matched automatically
Display
- High class graphical display
- Graphical and text menu
Information
- Alarm and error history
- Reading of flame brightness
- Fuel quantity in the hopper
- Current fuel consumption
- Current burner power
- Info key for quick help
- Alarm sound signalling
- Clock with calendar
Inputs/Outputs
- Central heating pump
- Domestic hot water pump with temperature sensor
- Mixing valve with temperature sensor
- Outdoor temperature sensor
- Room thermostat
- Boiler thermostat (Gas/Oil)
- Pressure sensor for flue gas fan monitoring
- Flue gas temperature sensor
- Safety temperature limiter
Extensions
- For mixing valves with temperature sensors
- Domestic hot water circulation pump
- Buffer circuit charging pump with temperature sensors
- Main hopper feeder with fuel sensor
- Lambda Control
- Net Control
Features of the S.Control TOUCH
onfiguration wizard
- Fast and easy configuration in several steps
- Air and fuel parameters are matched automatically
Display
- High class colour, touch display
- Graphical and text menu
Information
- Alarm and error history
- Reading of flame brightness
- Fuel quantity in the hopper
- Current fuel consumption
- Current burner power
- Info key for quick help
- Alarm sound signalling
- Clock with calendar
Inputs/Outputs
- Central heating pump
- Domestic hot water pump with temperature sensor
- Mixing valve with temperature sensor
- Outdoor temperature sensor
- Room thermostat
- Boiler thermostat (Gas/Oil)
- Pressure sensor for flue gas fan monitoring
- Flue gas temperature sensor
- Safety temperature limiter
Extensions
- For mixing valves with temperature sensors
- Domestic hot water circulation pump
- Buffer circuit charging pump with temperature sensors
- Main hopper feeder with fuel sensor
- Lambda Control
- Net Control
Dimensions, technical parameters of the boiler
| Boiler type | - | A0C-X20P-00.16 |
| Sections number | pcs. | 5 |
| Boiler weight (incl. the reservoir) | kg | 356 |
| Water content | l | 62 |
| Chimney throat diameter | mm | 156 |
| Boiler dimensions (incl. the reservoir): width x depth x high | mm | 1258 x 1207 x 1345 |
| Boiler dimensions (incl. the reservoir and the economizer): width x depth x high | mm | 1258 x 1639 x 1345 |
| Diameter of the filling hole for manual filling | mm | 500 |
| Diameter of the filling hole for automatic filling | mm | 50 |
| Operation water overpressure | bar | 4 |
| Testing water overpressure | bar | 8 |
| Recommended operation heating water temperature | ºC | 65 - 85 |
| Minimum return water temperature | ºC | 55 |
| Cold water temperature | ºC | 10 |
| Overpressure for the safety heat-exchanger (DBV 1 – 02) | bar | 6 |
| Boiler hydraulic loss (at ΔT 20 K) | mbar | 0,677 |
| Hydraulic resistance coefficient | 8,155 | |
| Noise level | dB | Not exceeding the level of 65 dB (A) |
| Chimney draught | mbar | 0,10 - 0,20 |
| Boiler connections – heating water – return water | G 1 ½" (6/4") | |
| Supply voltage | 1/N/PE 230V AC 50 Hz TN - S | |
| Electric cover | IP 40 | |
| Electric energy consumption at the nominal power | W | 43 |
Heating technical parameters of the boiler
| Boiler type | - | A0C-X20P-00.16 |
| Sections number | pcs. | 5 |
| Nominal power | kW | 20 |
| Fuel consumption at the nominal power | kg/h | 4,9 |
| Flue gases temperature at the nominal power - A0C-SXP/ A0C-AXP | ºC | 211/113 |
| Minimum power | kW | 6,4 |
| Fuel consumption at the minimum power | kg/h | 1,5 |
| Flue gases temperature at the minimum power - A0C-SXP/ A0C-AXP | ºC | 114,5/74 |
| Minimum chimney draught | mbar | 0,14 |
| Fuel heating power | MJ/kg | 16,78 |
| Effectiveness - A0C-SXP/ A0C-AXP | % | 83,3/90 |
| Mass flow rate of flue gases on the output side - A0C-SXP/ A0C-AXP | kg/s | 0,014/0,014 |
| Boiler class according to EN 303-5 - A0C-SXP/ A0C-AXP | 4/5 | |
| Energy efficiency class | A+ |

- Front section
- Central section
- Rear section
- Stocking door (with a rosette of primary air)
- Ash door
- Chimney pot
- Burner sealing
- Burner PellasX
- Connecting hose
- Feeder
- Reservoir
- Cladding (complete)
- Control cabinet
- Regulator control elements
- Heating water pipe
- Ash-pan
- Burner flange
- Flange insulation
- Return water pipe
- Baffle
- Upper insulation of the stocking door
- Bottom insulation of the stocking door
- Upper insulation of the ash door
- Bottom insulation of the ash door
- Securing valve
- Burner pipe
- Bushing
Product Details
Boiler with feeder
Cast iron boiler
5
A+
BImSchV 2
Internal
Vertical
YES
remote
via the Internet
via web browser
YES
YES
5 years for tightness of the heat exchanger
Comments
Your review appreciation cannot be sent
Report comment
Report sent