Description
ecoLAMBDA module is modern electronic device for measuring the oxygen content in the exhaust gas. The results of measurements of the module are sent ecoLAMBDA digital communication interface RS-485 module to work with regulators, whose job is to maintain the oxygen content and temperature of the gas at the required level by controlling the inflow of fluid.
SPECIFICATIONS
| ecoLAMBDA | |
| Measuring parameters | measuring range: 0 .21% O 2, an accuracy of ± 1% O2 ( Accuracy refers to the same input of the module and does not include the accuracy of the probe connected) |
| Data transmission | RS485 |
| Power | 230V AC, P=18W, 50Hz |
| Load carrying capacity terminals 3.4 | max. 2A |
| Operating Conditions | 0° ≤ Ta ≤ 60°C, relative humidity, non-condensing |
| Enclosure | IP 20 |
| Nominal new surge voltage | 2500V~ |
| Weight Module | 0,6kg |
| Dimensions | 140x90x65mm |