Air/water heat pump for domestic hot water up to 55ºC with a capacity of 300 litres and one spiral coil.

Heat pump air-water Galmet BASIC 300 L with 1 coil

Air/water heat pump for domestic hot water up to 55ºC with a capacity of 300 litres and one spiral coil.

Price: zł11,297.00
Bezpieczne płatności

Testowy opis płatności

Szybka dostawa

Kolejny testowy opsi

30 dniowe zwroty

Zwroty do 30 dniu bezpłatne

Kup teraz, a otrzymasz w Monday, 30 November!
  • Credit Agricole Bank
  • ING Lease now
Heat pump air-water BASIC 270 L with 1 coil
Price: zł11,297.00
Notify me of availability

Description

Air as a renewable energy source

Basic heat pump is an ideal source of domestic hot water for single-family houses. A heat pump with a storage tank provides 300 litres of domestic hot water up to 55°C. Installation of pump doesn't require expensive drilling as with ground pumps. Basic pump is designed for indoor installation and requires only hydraulic and electrical connections, as well as air ducts. Special control functions ensure that the use of the pump is safe and comfortable. PARTY function is an ideal solution when the house is temporarily occupied by a larger number of people and when express heating of domestic water is required. In order to take care of the health of users, pump has Anti-legionella function, which prevents proliferation of bacteria. Pump has a function of optimizing operation called ECO. The pump itself is protected by the anti-freeze function. Energy efficiency class A is proof of low energy consumption. As standard, Basic heat pump is equipped with a permanent monitoring function. Basic parameters of pump are continuously displayed on LCD touch screen of controller. This makes it possible to control circulation pump. Appropriate programming of hot water demand times and periods shortens waiting time for hot water in tap. It allows you to maintain water at desired temperature. In each Basic pump controller there is a database of optimal configurations of domestic water heating. It allows you to program the pump's hourly operating schedule, e.g. to benefit from the advantages of a night-time tariff. A dedicated room controller allows you to control pump functions and change parameters. As standard, the Basic pump allows partial cooling or dehumidification of room in which it operates. In order to ensure convenient and quick installation of each Basic heat pump, necessary ventilation elements are offered.

Technical data Unit BASIC 300 with 1 voil
Thermal effciency class ErP [-] A
COP [-] 2,69
Directory Number
[-] 09-356100
Heat output of heat pump
[kW] 2
Nominal power consumption of heat pump
[W] 670
Total heating power (heat pump + heater)
[kW] 4
Surface of spiral coil
[m2] 1,0
Max. temperature c.w.u. [ºC] 55
Supply voltage and frequency
[V/Hz] 230/50
Temperature operating range [ºC] -7 - +35
Tank capacity
[l] 300
Connection spigots
[cal] 1"
Circulation connection spigot
[cal] 3/4
Maximum working pressure of tank
[MPa] 1,0
Maximum operating pressure of exchanger
[MPa] 1,6
Acoustic power level
[dB] 62
Minimum airflow
[m3/h] 300
Diameter of air ducts
[mm] 160
Maximum length of air ducts
[m] 10
Dimensions (H x W x D.) [mm] 1900 x 670
Weight [kg] 135
Energy effciency of water heating
[%] 80
 Basic 270 1W

Connection spigots / pump description

  1. Controller
  2. Insulation
  3. Central heating coil
  4. Heat pump coil
  5. Evaporator with fan
  6. Compressor
  7. Filter
  8. Expansion valve
  9. Condensation drain
  10. Collection of c.w.u. GW1"
  11. Hot water supply for central heating GW1"
  12. Circulation GW 3/4"
  13. Sensor cover R3/8"
  14. Return of central heating water GW1"
  15. Cold water supply GW1"
  16. Trigger connection

Power supply of heat pump from boiler room and air outlet to outside

galmet



IMPORTANT: It is necessary to ensure adequate ventilation of the room where the heat pump is located.

Location of heat pump inside the boiler room

galmet



IMPORTANT: A minimum distance of 1.5 m should be maintained between the suction and discharge ducts.

Power supply and air ejection from heat pump to outside

galmet

Power supply of heat pump from outside and air flow to another room

galmet

Controller TECH ST 53.2

Controller ST 53.2
Modern Touch Controller for Basic heat pump - ST-53.2 with functions: ECO, ECO PLUS, MANUAL OPERATION, COMPRESSOR FAILURE, ANTI-LEGIONELLA, STOP, PARTY, INSTALLATION FAILURE.

Product Details

Brand
Condition
New
Product type
Air heat pump
heat pump
Power [ kW ]
4
Class
A
Weight [ kg ]
135
Height [ mm ]
1900
Water capacity [ L ]
270
Diameter [ mm ]
670
Outlet and inlet supply size [ inch ]
1''
Installation
Floor
Internal
Vertical
Max. operating pressure [ bar ]
10
Heater
electric
OPTIONAL
YES
Size [ mm² ]
100000
Mains voltage [ V ]
230
Warranty
5 years
Coil
1 coil
YES

Comments

4 other products in the same category

1000+

Produktów w ofercie

24h

Szybka dostawa

5/5

Wysoka jakość obsługi

5000+

Zadowolonych klientów

Loading...
Back to top