The METAL-FACH SDG is a central heating boiler designed to burn firewood and hard coal. Firewood is the primary fuel, while hard coal can be used as an additional fuel. The series comprises four models with nominal heat outputs of 10, 15, 20 and 25 kW.
Wood and Coal-Fired Boiler Metal-Fach SDG 10 - 25 kW
The METAL-FACH SDG is a central heating boiler designed to burn firewood and hard coal. Firewood is the primary fuel, while hard coal can be used as an additional fuel. The series comprises four models with nominal heat outputs of 10, 15, 20 and 25 kW.
- New
- Out-of-Stock
Description
METAL-FACH SDG Wood and Coal-Fired Boiler 10–25 kW
The METAL-FACH SDG is a central heating boiler designed to burn firewood and hard coal. Firewood is the primary fuel, while hard coal can be used as an additional fuel. The series comprises four models with nominal heat outputs of 10, 15, 20 and 25 kW.
The boiler is equipped with vertical convection channels, flue gas turbulators and ceramic plates in the combustion chamber. These components support the combustion process and heat transfer through the heat exchanger. The boiler is operated using, among other components, a draught regulator, a mechanical thermometer, a smoke extraction flap and a grate-shaking lever.
The METAL-FACH SDG meets Class 5 and Ecodesign requirements. Its energy efficiency class is A+ when burning firewood and B when burning hard coal. According to the manufacturer's requirements, the boiler installation must include a buffer tank.
Key Features of the METAL-FACH SDG Boiler
- Nominal heat output range from 10 to 25 kW.
- Firewood as the primary fuel.
- Hard coal as an additional fuel.
- Compliance with Class 5 and Ecodesign requirements.
- Vertical convection channels in the heat exchanger.
- Flue gas turbulators supporting heat transfer to the water jacket.
- Ceramic plates in the combustion chamber.
- Draught regulator controlling the air supply.
- Mechanical bimetallic thermometer.
- Separate adjustment of primary and secondary air supply.
- Smoke extraction flap and grate-shaking lever.
- Access to the heat exchanger from the front of the appliance.
- A buffer tank is required in the heating system.
Design and Equipment
Draught Regulator
The draught regulator controls the air supply to the combustion chamber. Depending on the temperature of the heating medium, it changes the position of the air inlet flap, helping to maintain suitable boiler operating conditions.
Mechanical Thermometer
The mechanical bimetallic thermometer, equipped with a long measuring probe, allows the boiler operating temperature to be monitored.
Primary and Secondary Air Adjustment
Two adjustment openings located at the front of the boiler allow the primary and secondary air supplies to be adjusted independently. Correct adjustment supports proper combustion.
Ceramic Plates
The ceramic plates in the combustion chamber help maintain a high temperature in the firebox and support the burnout of particles produced during fuel combustion. This solution helps improve combustion conditions and the utilisation of the energy contained in the fuel.
Heat Exchanger and Vertical Convection Channels
The heat exchanger features vertical convection channels that allow heat to be recovered from the flue gases and transferred to the boiler's water jacket. The design allows the heat exchanger to be cleaned from the front of the appliance.
Flue Outlet
The flue outlet, located at the rear of the boiler, allows the appliance to be connected to the chimney system.
Smoke Extraction Flap
The smoke extraction flap allows smoke to be removed from the combustion chamber during boiler operation and servicing.
Grate-Shaking Lever
The grate-shaking lever facilitates grate cleaning and the removal of ash residues before the fuel is loaded again.
Flue Gas Turbulators
The turbulators installed in the convection channels change the direction of flue gas flow and extend the time the gases remain in contact with the heat exchanger surface. This facilitates heat transfer to the water jacket.
Technical Data of the METAL-FACH SDG Boiler
| Parameter | SDG 10 | SDG 15 | SDG 20 | SDG 25 |
|---|---|---|---|---|
| Nominal heat output [kW] | 10 | 15 | 20 | 25 |
| Primary fuel | Firewood compliant with standard PN-EN 303-5+A1:2023-05 | |||
| Additional fuel | Hard coal compliant with standard PN-EN 303-5+A1:2023-05 | |||
| Water capacity [l] | 37 | 42 | 49 | 56 |
| Log circumference [cm] | 30 | 30 | 30 | 30 |
| Log length [cm] | 24 | 24 | 29 | 29 |
| Required heat storage tank (buffer tank) capacity [l] | 330 | 555 | 800 | 1005 |
| Boiler weight [kg] | 240 | 260 | 307 | 334 |
Emissions and Efficiency
| Parameter | SDG 10 | SDG 15 | SDG 20 | SDG 25 |
|---|---|---|---|---|
| Seasonal particulate matter emissions [mg/m³] | 29 / 36 | 20 / 32 | 33 / 36 | — |
| Efficiency at nominal output [%] | 88.4 / 88.7 | 89.0 / 88.9 | 88.8 / 88.6 | — |
| Particulate matter emissions at nominal output [mg/m³] | 26 / 34 | 20 / 29 | 32 / 37 | — |
| Efficiency at minimum output [%] | — | — | — | — |
| Particulate matter emissions at minimum output [mg/m³] | — | — | — | — |
The emissions and efficiency values are presented in the order and format provided in the manufacturer's specifications. Detailed parameters for individual fuels should be checked in the technical documentation for the relevant model.
Certificates and Classification
| Parameter | SDG 10 | SDG 15 | SDG 20 | SDG 25 |
|---|---|---|---|---|
| ZUM List identification number | — | — | — | — |
| Clean Air Programme | — | — | — | — |
| Ecodesign | Yes | Yes | Yes | Yes |
| Boiler class | 5 | 5 | 5 | 5 |
| Energy efficiency class – firewood | A+ | A+ | A+ | A+ |
| Energy efficiency class – hard coal | B | B | B | B |
According to the manufacturer's information, the boiler is not eligible for the Clean Air Programme and is not listed on the ZUM List.
Boiler Dimensions

| Dimension | SDG 10 | SDG 15 | SDG 20 | SDG 25 |
|---|---|---|---|---|
| A | 415 | 415 | 460 | 460 |
| B1 | — | — | — | — |
| B2 | — | — | — | — |
| C1 | 860 | 920 | 930 | 985 |
| C2 | — | — | — | — |
| D1 | 1145 | 1145 | 1245 | 1300 |
| D2 | 860 | 860 | 960 | 1005 |
| E | — | — | — | — |
| F1 | 585 | 645 | 675 | 725 |
| F2 | 170 | 160 | 170 | 170 |
| F3 | 280 | 270 | 380 | 430 |
| F4 | — | — | — | — |
| G1 | 159 | 159 | 159 | 159 |
| G2 | 1 1/2" | 1 1/2" | 1 1/2" | 1 1/2" |
| G3 | 1 1/2" | 1 1/2" | 1 1/2" | 1 1/2" |
| G4 | 3/4" | 3/4" | 3/4" | 3/4" |
| H | 30 | 30 | 30 | 30 |
| W | 240 × 200 | 240 × 200 | 290 × 200 | 290 × 200 |
| X | 265 | 265 | 355 | 400 |
| Y | 400 | 460 | 450 | 500 |
| Z | 240 | 240 | 290 | 290 |
The dimensions should be read according to the manufacturer's dimensional drawing. Before installation, check the required installation clearances and connection dimensions in the technical and operating documentation.
Buffer Tank – Installation Requirements
The METAL-FACH SDG boiler installation requires a buffer tank of appropriate capacity. The buffer tank stores excess heat generated during fuel combustion and allows it to be used later in the heating system.
| Boiler model | Required buffer tank capacity [l] |
|---|---|
| SDG 10 | 330 |
| SDG 15 | 555 |
| SDG 20 | 800 |
| SDG 25 | 1005 |
Note: The SDG boiler may only be installed in a system equipped with a buffer tank. The buffer tank is additional equipment and is not included in the boiler price.
Warranty
The manufacturer provides a standard 2-year warranty, which can be extended to 5 years. The extended warranty is subject to the conditions specified in the technical documentation.
Important Operating Information
The boiler must be installed, commissioned and operated in accordance with the manufacturer's technical and operating documentation. Modifying the boiler's construction or installing additional components that enable the combustion of fuels other than those specified by the manufacturer is prohibited. Such actions may result in the loss of warranty coverage.
Before purchasing, the boiler output should be matched to the building's heat demand. The requirements for the chimney, hydraulic installation and buffer tank should also be checked.