The best controller for small central heating systems that can support 2 pumps (central heating and domestic hot water) and a blower (fan), screw feeder with a lot of software functions for automatic boiler combustion.
Central heating controller ELECTRONICS SP18
The best controller for small central heating systems that can support 2 pumps (central heating and domestic hot water) and a blower (fan), screw feeder with a lot of software functions for automatic boiler combustion.
Description
Central heating controller SP-18 is a modern and easy to use electronic controller for central heating systems from ELECTRONICS. SP-18 is designed to help to create a fully automated combustion process in modern central heating automatic boilers with screw feeder supply system.
Central heating controller with the ability to control up to two pumps (domestic hot water and central heating), boiler feeder and blower for simple central heating installations in single detached homes, cottages and other places with lots of extra functions for comfortable and economical combustion of automated solid fuel fired boilers.
SP-18 central heating controller functions
- simple to use and manage central heating controller
- blower control in full range of fan speed
- wide blower power range airflow control of 10-99%
- readable LCD display
- Adjustable temperature of central heating pump start
- function of maintaining the desired temperature setpoint
- CH or DHW temperature priority switch
- Summer mode (heating of only DHT water) function
- DHW hysteresis (function gives the possibility of setting at which temperature setpoint the connected DHT pump shall work again)
- LED signaling of equipment operation like feeder, blower, CH or DHT pump on the front panel
- eco mode, automatic reduction of the solid fuel amount supplied to boiler when reaching the desired temperature setpoint (function defining how much degrees before the temp. setpoint the feeder will reduce the amount of solid fuel, this feature prevents excessive build-up of un-burned fuel (for ex. poor quality coal) on the edge of the burner - slag or sinter in the burner corona)
- alarming function by displaying text and playing audio in case when damaged sensors or CH/DHT temperature is too high, empty solid fuel storage tank, boiler feeder temp. to high
- full control settings for boiler solid fuel dosage delivery and breaks
- fully adjustable blower working
- sustaining boiler operation mode (setting the solid fuel dosage only to sustain the heat)
- extinguish function, switch off the feeder and the blower after solid fuel combustion is complete
- restore to the factory settings in case of bad configuration
- blower starting function (allows to set the start time for blowing at full power, function eliminates problems with the start of fans that after several seasons of work partially lost their efficiency)
- monitoring function to delay freezing of the central heating system (automatic ZH pump on at temperatures lower than 6 ° C) - antifreeze
- manual operation mode of the controller allows independent manual switching of individual devices connected with the controller
- possibility of connecting a room regulator to control the boiler without the need of visting the boiler room
- digital driver saves the settings to the device internal memory
- works with all blowers intended for use in solid fuel fired boilers
- controller works with standard and energy saving pumps
- controller returns to automatic operation after power is restored
- controller hermetic sensor
- control housing adapted for mounting on the boiler
Central heating installation digital controller for automatic boilers

- cold water
- hot water
- electrical power supply cords
- electrical low-voltage control cables
- DHW storage tank
- DHW pump
- four-way mixing valve
- additional short circuit pump
- boiler feeder temperature sensor
- boiler water temperature sensor
- CH pump
- SP-18 controller
- room thermostat
- CH installation radiator
- DHW temperature sensor
| Controller parameter | Unit | Value |
| AC Power supply | W | 230V/50Hz +/-10% |
| CH controller maximum power consumption | V | 4-8 |
| Working temperature | °C | 0÷50 |
| Maximum CH pump output load | A | 1 |
| Output blower load | A | 1 |
| Measurement accuracy | °C | 1 |
| Temperature setpoint range | °C | 35÷80 |
| Thermal temperature sensor durability | °C | -25÷99 |
| Electrical fuse | A | 1x3,5 |
Product Details
Central heating pump controller
CH and CUW pump controller
Controller
Feeder controller
Pump controller
Internal
YES
YES
CH pump
CUW pump
ventilator
central heating pump
CH and CUW priority
domestic hot water pump
Freezing protection
Overheating potection
PWM (Pulse-Width Modulation)
Summer mode
YES
Feeder temperature
temperature of DHW
YES