The Metal-Fach SEMAX BASIC PLUS boiler is a wood gasification boiler designed for single-family houses.
- New
- Out-of-Stock
Description
SEMAX BASIC PLUS 15–20 kW – wood gasification boiler
SEMAX BASIC PLUS is a series of central heating boilers designed for the gasification of piece firewood. The model is available in two output variants: 15 and 20 kW. The boiler combines a gasification and combustion chamber with design solutions supporting heat transfer and the combustion process.
SEMAX BASIC PLUS is equipped with a mechanical draught regulator, mechanical bimetal thermometer, turbulators, horizontal convection channels, ceramic plates and an exhaust system consisting of an ST 880 PiD controller and an exhaust fan. The exhaust system provides automatic operation of the system and maintains optimal flue gas draught.
IMPORTANT! The central heating boiler may only be installed in a heating system together with a buffer tank. The buffer tank is not included in the boiler price.
Wood gasification technology
The SEMAX BASIC PLUS boiler uses a gasification and combustion chamber in which wood undergoes a thermal processing process. The supply of primary and secondary air can be adjusted using slides, allowing the combustion process to be adjusted.
Ceramic plates are installed in the combustion chamber. They increase the process temperature and help burn particles rising above the firebed.
Construction and design solutions
- Draught regulator – depending on the temperature of the heating medium, it controls the flap regulating the air supply to the boiler combustion chamber.
- Mechanical bimetal thermometer – equipped with a long measuring probe.
- Turbulators – create turbulence in the flue gases, supporting heat exchange between the flue gases and the water jacket.
- Horizontal shelf-type convection channels – the heat exchanger design provides high heat transfer and enables automatic front cleaning of the heat exchanger.
- Rear flue outlet – allows the flue connection to be routed directly to the chimney.
- Primary and secondary air intake – air is supplied through six openings, and the amount of primary and secondary air can be adjusted using slides.
- Smoke flap – allows smoke to be discharged from the combustion chamber.
- Ceramic plates – increase the temperature in the combustion chamber and help burn particles rising above the firebed.
- Exhaust system – consists of an ST 880 PiD controller and an exhaust fan. It provides automatic operation, maintains optimal flue gas draught and enables electronic adjustment of the exhaust force.
- Buffer tank – provides appropriate operating conditions for the boiler. Excess heat is stored in the buffer tank and can then be drawn by the heating system according to current demand.
ST 880 PiD exhaust system
SEMAX BASIC PLUS is equipped with an exhaust system consisting of an ST 880 PiD controller and an exhaust fan. The system provides automatic operation and maintains optimal flue gas draught.
Electronic adjustment of the exhaust force allows the operation of the exhaust system to be adjusted.
Simple operation and control
The boiler is equipped with mechanical control elements and an exhaust system. The draught regulator controls the air supply to the combustion chamber, while the mechanical bimetal thermometer enables monitoring of the heating medium temperature.
The ST 880 PiD controller together with the exhaust fan provides automatic operation of the exhaust system and adjustment of the exhaust force.
Buffer tank
A buffer tank is a required element of the SEMAX BASIC PLUS boiler installation. It is additional equipment and is not included in the boiler price.
The buffer tank enables excess heat generated during boiler operation to be stored. The heating system can subsequently draw the amount of heat from the buffer corresponding to the current demand.
Ecology and efficiency
SEMAX BASIC PLUS is a boiler designed for the gasification of piece firewood. The use of a gasification chamber, ceramic plates, turbulators and convection channels supports the use of energy contained in the fuel.
The boiler meets the requirements of Class 5 and EcoDesign and has an A+ energy class. The 15 and 20 kW models are also included on the ZUM List and qualify for the Czyste Powietrze programme.
Technical specifications
| Parameter | SEMAX BASIC PLUS 15 | SEMAX BASIC PLUS 20 |
|---|---|---|
| Nominal heat output [kW] | 15 | 20 |
| Fuel | Piece firewood compliant with standard 303-5:2021-09 | |
| Water capacity [l] | 71 | 77 |
| Log circumference [cm] | 30–40 | 30–40 |
| Log length [cm] | 34 | 44 |
| Boiler weight [kg] | 342 | 390 |
| Buffer tank capacity [l] | 555 | 780 |
Emissions and efficiency
| Parameter | SEMAX BASIC PLUS 15 | SEMAX BASIC PLUS 20 |
|---|---|---|
| Seasonal particulate matter emissions [mg/m³] | 20 | 18 |
| Efficiency at nominal output [%] | 90 | 88.7 |
| Nominal particulate matter emissions [mg/m³] | 20 | 17 |
| Efficiency at minimum output [%] | - | - |
| Minimum particulate matter emissions [mg/m³] | - | - |
Certificates and classification
| Parameter | SEMAX BASIC PLUS 15 | SEMAX BASIC PLUS 20 |
|---|---|---|
| ZUM List ID | KZ-400754 | KZ-500763 |
| Czyste Powietrze | Yes | Yes |
| EcoDesign | Yes | Yes |
| Boiler class | 5 | 5 |
| Energy class | A+ | A+ |
Dimensions
| Dimension | Unit | SEMAX BASIC PLUS 15 | SEMAX BASIC PLUS 20 |
|---|---|---|---|
| A – boiler width | [mm] | 490 | 520 |
| B – boiler depth | [mm] | 957 | 1070 |
| C – boiler height | [mm] | 1275 | 1275 |
| D – height to flue outlet | [mm] | 1050 | 1050 |
| E – flue outlet diameter | [mm] | 159 | 159 |
| X – hopper width | [mm] | 290 | 290 |
| Y – hopper height | [mm] | 515 | 515 |
| Z – hopper depth | [mm] | 345 | 445 |
| Door dimensions | [mm] | 290 × 200 | 290 × 200 |
| I – foot height adjustment | [mm] | 30 | 30 |
Key features of SEMAX BASIC PLUS
- 2 output variants: 15 and 20 kW,
- boiler designed for the gasification of piece firewood,
- Class 5 boiler,
- compliance with EcoDesign requirements,
- A+ energy class,
- included on the ZUM List for both output variants,
- qualification for the Czyste Powietrze programme,
- mechanical draught regulator,
- mechanical bimetal thermometer,
- horizontal shelf-type convection channels,
- turbulators in the convection channels,
- ceramic plates in the combustion chamber,
- primary and secondary air adjustment,
- smoke flap,
- rear flue outlet,
- ST 880 PiD exhaust system with exhaust fan,
- buffer tank as a required element of the installation.
SEMAX BASIC PLUS 15–20 kW is a series of wood gasification boilers designed for central heating systems. The available 15 and 20 kW output variants allow the boiler to be selected according to the parameters of the heating system. The boiler features a gasification and combustion chamber, ceramic plates, horizontal convection channels, turbulators and an ST 880 PiD exhaust system with an exhaust fan, enabling automatic operation of the exhaust system and adjustment of the exhaust force.
Does the SEMAX BASIC PLUS boiler require a buffer tank?
Yes. The SEMAX BASIC PLUS boiler may only be installed in a heating system together with a buffer tank. The tank is not included in the boiler price. Its purpose is to store excess thermal energy generated during boiler operation.
Important information regarding the boiler construction: any interference with the boiler construction is prohibited and results in loss of warranty. Attempts to install additional grates or elements enabling the combustion of fuel other than that specified by the manufacturer are also prohibited.
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent