BUFFERS, NON-ENAMELLED VESSELS WITHOUT SPIRAL COILS - TYPE SG(B), Storage capacity from 200 - 5000 Liter
Description
Buffer (accumulation) tanks are designed to store heat energy that has been generated by an external heat source. Such a heat source can be e.g. central heating boiler, heat pump, fireplace, solar collectors. A buffer tank installed in system allows to limit frequency of switching on central heating boiler or heat pump and allows to maintain stable temperature in whole system. It can operate in open as well as closed systems and at the same time it serves as a so called "coupling in the system". Heat stored in tank can be directly transferred to central heating system or heat up domestic hot water. Buffers have a large number of connections that allow them to be connected in different variants of heating systems and supplied with different temperatures of heating medium. Depending on capacity, tanks have polyurethane hard foam insulation, or in larger capacities, removable NEODUL foam insulation is used. Storage tanks are not enamelled, therefore they are adapted to store heat in natural medium such as demineralised boiler water, glycol, etc.
The manufacturer provides a 60-month warranty
Isolation
- Capacities 200 - 500 litres - SKAY polyurethane foam
- Capacities 800 - 2000 litres - NEODUL®
- Capacities 3000 - 5000 litres - SKAY polyurethane foam
Connection pipes are located at an angle of 45º on right and left side facing tank. Tanks from 200 to 400 litres have adjustable feet, volumes from 500 to 5000 litres are placed on a ring instead of feet.
| Technical data | Unit | SG(B) 200 | SG(B) 300 | SG(B) 400 | SG(B) 500 |
| ErP energy efficiency class | - | B | B | C | C |
| Storage capacity1 | l. | 223 | 305 | 396 | 467 |
| Max. operating pressure of tank | MPa | 0.3 | |||
| Max. tank operating temperature | °C | 100 | |||
| h1 - boiler water connection - Gw 6/4” | mm | 220 | 250 | ||
| h2 - boiler water connection - Gw 6/4” | mm | 220 | 250 | ||
| h3 - boiler water connection - Gw 6/4” | mm | - | 390 | 445 | 485 |
| h4 - sensor/thermometer connection Gw 1/2" | mm | 315 | 500 | 565 | 565 |
| h5 - boiler water connection - Gw 6/4” | mm | 485 | 560 | 635 | 715 |
| h6 - boiler water connection - Gw 6/4” | mm | 555 | 730 | 825 | 945 |
| h72 | mm | 605 | 900 | 1115 | 1185 |
| h8 - sensor/thermometer connection - Gw 1/2" | mm | 785 | 900 | 1115 | 1180 |
| h9 - boiler water connection - Gw 6/4" | mm | 785 | 1070 | 1210 | 1410 |
| h10 - boiler water connection - Gw 6/4" | mm | 885 | 1235 | 1400 | 1640 |
| h11 - sensor/thermometer connection - Gw 1/2" | mm | 885 | 1235 | 1400 | 1640 |
| L - height | mm | 1140 | 1480 | 1685 | 1925 |
| d - inner diameter of tank | mm | 550 | 600 | ||
| D - outer diameter of tank | mm | 670 | 700 | ||
| Weight | kg | 60 | 75 | 90 | 105 |


| Technical data | Unit | SG(B) 800 | SG(B) 1000 | SG(B) 1500 | SG(B) 2000 |
| ErP energy efficiency class | - | C | C | C | C |
| Storage capacity1 | l. | 728 | 883 | 1479 | 2023 |
| Max. operating pressure of tank | MPa | 0.3 | |||
| Max. tank operating temperature | °C | 100 | |||
| h1 - boiler water connection - Gw 6/4” | mm | 250 | 250 | 375 | 385 |
| h2 - boiler water connection - Gw 6/4” | mm | 250 | 250 | 375 | 385 |
| h3 - boiler water connection - Gw 6/4” | mm | 435 | 500 | 700 | 660 |
| h4 - sensor/thermometer connection Gw 1/2" | mm | 570 | 570 | 915 | 800 |
| h5 - boiler water connection - Gw 6/4” | mm | 620 | 740 | 1015 | 930 |
| h6 - boiler water connection - Gw 6/4” | mm | 820 | 980 | 1325 | 1205 |
| h72 | mm | 1020 | 1240 | 1640 | 1480 |
| h8 - sensor/thermometer connection - Gw 1/2" | mm | 1020 | 1240 | 1640 | 1480 |
| h9 - boiler water connection - Gw 6/4" | mm | 1215 | 1485 | 1950 | 1755 |
| h10 - boiler water connection - Gw 6/4" | mm | 1410 | 1730 | 2260 | 2025 |
| h11 - sensor/thermometer connection - Gw 1/2" | mm | 1410 | 1730 | 2260 | 2025 |
| L - height | mm | 1730 | 2050 | 2700 | 2500 |
| d - inner diameter of tank | mm | 790 | 790 | 900 | 1100 |
| D - outer diameter of tank | mm | 950 | 950 | 1100 | 1300 |
| Height on skew | mm | 1995 | 2270 | 2920 | 2820 |
| Weight | kg | 125 | 150 | 210 | 235 |

| Technical data | Unit | SG(B) 3000 | SG(B) 4000 | SG(B) 5000 |
| Storage capacity1 | l. | 2935 | 3985 | 4981 |
| Max. tank operating pressure | MPa | 0.3 | ||
| Max. tank operating temperature | °C | 100 | ||
| h1 - boiler water connection - Gw 6/4” | mm | 410 | 445 | 445 |
| h2 - boiler water connection - Gw 6/4” | mm | 410 | 445 | 445 |
| h3 - boiler water connection - Gw 6/4” | mm | 725 | 675 | 760 |
| h4 - sensor / thermometer connection Gw 1/2" | mm | 825 | 790 | 920 |
| h5 - boiler water connection - Gw 6/4” | mm | 1040 | 910 | 1075 |
| h6 - boiler water connection - Gw 6/4” | mm | 1360 | 1140 | 1390 |
| h72 | mm | 1680 | 1365 | 1705 |
| h8 - sensor / thermometer connection - Gw 1/2" | mm | 1680 | 1365 | 1705 |
| h9 - boiler water connection - Gw 6/4" | mm | 1995 | 1605 | 2020 |
| h10 - boiler water connection - Gw 6/4" | mm | 2310 | 1840 | 2335 |
| h11 - sensor / thermometer connection - Gw 1/2" | mm | 2310 | 1840 | 2335 |
| L - Height | mm | 2750 | 2355 | 2855 |
| d - internal diameter of tank | mm | 1250 | 1600 | 1600 |
| D - outer diameter of tank | mm | 1450 | 1800 | 1800 |
| Height on skew | mm | 3120 | 2970 | 3380 |
| Weight | kg | 300 | 380 | 440 |
1In accordance with Commission Regulation (UE) 812/2013, 814/2013.
2For 200 l capacity sensor/thermometer connection Gw 1/2", for larger capacity boiler water connection Gw 6/4”.
Height of slope:
| Height mm | Diameter with insulation | Diameter without insulation | Diagonal with insulation | Diagonal without insulation | |
| 300 L | 1480 | 670 | - | 1645 | - |
| 400 L | 1685 | 700 | - | 1845 | - |
| 500 L | 1925 | 700 | - | 2069 | - |
| 800 L | 1730 | 950 | 790 | 1994 | 1922 |
| 1000 L | 2050 | 950 | 790 | 2280 | 2217 |
| 1500 L | 2700 | 1100 | 900 | 2936 | 2867 |
| 2000 L | 2500 | 1300 | 1100 | 2838 | 2752 |
| 3000 L | 2750 | 1450 | 1250 | 3129 | 3041 |
| 4000 L | 2355 | 1800 | 1600 | 2985 | 2868 |
| 5000 L | 2855 | 1800 | 1600 | 3396 | 3293 |
Product Details
Tank
Internal
Vertical
Polyurethane foam
YES
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent