Charging boiler Defro HG

Power output [ kW ]
Zplynovací kotel Defro HG

Description

The HG boiler is used for heating single-family houses and smaller public utilities. It is intended for heating water in a central heating system to a boiler outlet temperature not exceeding 90 ° C and working pressure of not more than 2.0 bar for open systems or closed system up to a boiler outlet temperature not exceeding 90 ° C and working pressure of not more than 2.5 bar.

HG boiler used two-stage combustion process - gasification of fuel and subsequent pyrolysis that is combustion of formed gases. Wood fuel is used as a primary fuel. Boiler heat exchanger is made of high quality attested boiler plate with 6-8 mm thickness, in form of two chambers located above each other - connecting function of combustion chamber and ash-pan. Grate is located between the chamber allowing ideal gasification of wood and easy removal of ash. HG boiler is equipped with exhaust fan that protects it against backflow of smoke to the boiler room. Boiler can be assembled in the closed system.

Required cooperation with a storage tank.

The Defro HG boiler meets the energy and emission requirements of the 5th class of PN EN 303-5: 2012 standard and has the Ecodesign Certificate.

Standard equipment:

  • HG 2PID controller,
  • PID function,
  • version to the closed system,
  • exhaust fan,
  • analog thermometer,
  • upper cleaning door,
  • BVTS thermostatic valve,
  • exhaust fan,
  • cooling coil,
  • mechanical exchanger cleaning system.

Optional equipment (at extra charge):

  • GSM module,
  • DK LOGIC 100 controller

Elements of additional equipment should be reported when ordering the boiler due to the lack of possibility of subsequent installation.

HG 2 zPID controller

HG 2 PID controller servicing buffer, 3 pumps, mixing valve and exhaust fan;

3 years Warranty

3 years warranty for heat exchanger tightness, 2 years for the remaining components and efficient operation of boiler;

high-grade boiler steel

Heat exchanger made of certified high-grade boiler steel;

Efficency

High thermal efficiency reaching 90% due to increased heat recovery from flue gases;

closed system

Boiler adapted for installation in closed system;

Czyszczenie wymiennika ciepła

System for mechanical cleaning of heat exchanger;

Two-stage combustion process

Two-stage combustion process - fuel gasification and pyrolysis;

Exhaust fan

Exhaust fan eliminating problem with chimney draught and stabilising operation of the boiler;

Ceramic catalysts

Ceramic catalysts stabilising combustion process;

Dimensions

Type / Dimensions

A*

B*

C

D*

E*

F*

G

H

I J

poz.6

poz.15

poz.14

25 145 1194 Ø127 1225 712 630 76 1048 245 1369 G 1 ½" G 1 ½" G ½"

Boiler model

Defro HG
Specification / type of boiler Unit 25
Nominal power kW 25

The boiler class according to PN-EN 303-5

- 5

ECODESIGN

- YES

Energy class

- A+
Exhaust temperature
for nominal power

[ºC]
178-187

Basic fuel

- wood logs, ~ 12cm, humidity 15-20%

Heating surface

m2

2,6

Area of heated rooms *

m2

to 230

Capacity of the loading chamber

kg ∼93

Min. Safe storage tank capacity**

dm3 2500

Optimal thermal efficiency

% 90%

Max. permissible working pressure

bar open system 2,0 /close system 2,5

Return water temperature min.

ºC 60

Temperature regulation range

ºC 60 - 85

Required exhaust sequence

Pa 20

Water temperature on supply the min./max.

°C 65/85

Boiler weight

kg 542

Water capacity of boiler

l 172

Cross-section of chimney

cmxcm 15x15

Cross-section of chimney

Ø mm 170

minimum height of chimney

m 9

Width

mm 712

Depth

mm 1369
Height ***
mm 1225

Diameter of supply and return connector

mm 1½’’

Power

V/Hz ∼230/50

maximum permissible ambient temperature

ºC 50

diameter of the exhaust outlet

mm 127

Coil operating pressure min./max.****

bar 2/6

Dimensions of charging chamber

and fuel charging hole

width

330

depth

568

height

498

width x height

330x284

* Maximum area of heated rooms estimated for unit heat demand q=100 W/m2

** minimum safe storage tank capacity calculated in accordance with PN-EN 303-5

*** height of the DEFRO HG boiler can be additionally adjusted using attached feet. The feet have a 38-50mm adjustment range.

**** in case of higher pressure, use a pressure reducer.

Product Details

Brand
Condition
New
Efficiency [ % ]
90
Class
5
Width [ mm ]
7152
Outlet and inlet supply size [ inch ]
6⁄4''
Grate bar
YES
Ventilator
Extraction
Steering
YES
Mains voltage [ V ]
230
Fuel
wood
Warranty
3 years for the tightness of welded joints

Comments

Viewed products