Reference: 38721

Wood gasifying boiler ATMOS Dokogen DC GD

Reference: 38721
  • Out-of-Stock
Price: zł15,150.00
Model-/-Name

Notify me of availability

Out-of-Stock
Wood gasifying boiler ATMOS Dokogen DC
Price: zł15,150.00
Notify me of availability

Description

Dokogen DC GD boilers are wood gasifying boilers, it is the most efficient method, which consists in burning wood gas produced during thermal decomposition of wood with limited access to oxygen. Access to air and the combustion process are regulated by an exhaust fan. This makes it possible to start the boiler quickly and obtain a good quality of combustion from the moment it is started. The flame temperature is 1 000 - 1 250 °C.

Dokogen boilers are characterised by a unique fireplace, lined with ceramic fittings. At the bottom, the furnace has holes for the supply of heated primary air, a gasifying nozzle with holes for the supply of secondary air and a lower chamber with a ceramic spherical space. The rear flue gas duct, on the other hand, has a tubular exchanger.

Komora zasypowej

View of the charging chamber

Widok dolnej komory spalania

View of the lower combustion chamber

Wentylator wyciągowy i króciec dymowy

Exhaust fan and smoke autlet

Wymiennik rurowy

Pipe heat exchanger

Advantages of ATMOS wood gasifying boiler

  • ability to burn large pieces of wood;
  • large fuel tank (long combustion time);
  • tubular heat exchanger;
  • Sprawność wynosi powyżej 90%;
  • Ecological combustion (5th class according to ČSN EN 303-5, ECODESIGN 2015/1189);
  • Exhaust fan (ash removal without dust);
  • Cooling coil (protection against overheating of the boiler);
  • Automatic shutdown of the fan after fuel burnout;
  • Large ash collector (when burning wood, cleaning once a week);
  • Small and lightweight;
  • High quality
Boilers meet the limits for Ecological Products. According to ČSN EN 303-5, the boilers meet the requirements of the 5th class. They meet the strict requirements of EU - EKODESIGN 2015/1189.

ATMOS boilers must be connected via LADDOMAT or thermoregulation valve (can be purchased from us in the shop) in order to reach the minimum return water temperature of 65°C. Outgoing water from the boiler must be kept at 80 - 90°C.

Boiler control

Boiler regulation is electromechanical, it is provided by the air control valve controlled by the draught regulator type FR 124, which according to the set output water temperature (80 - 90 °C) automatically opens or closes the air valve. A lot of attention must be paid to the setting of the output regulator, as it protects the boiler against overheating. The boiler is equipped with a control thermostat located on the boiler panel, which controls the exhaust fan according to the set output temperature (80 - 85 °C). The temperature on the control thermostat should be set 5 °C lower than the temperature on the draught regulator type FR 124. Boilers are additionally equipped with a flue gas thermostat, which is used to switch off the exhaust fan after burning fuel.

Klapka regulacji powietrza

Air adjustment flap

Regulator ciągu

Thrust regulator type FR 124

Basic components of the boiler Atmos Dokogen DC

Atmos Dokogen DC
    1. Boiler body;
    2. Loading door (top);
    3. Ashtray door - combustion chamber (lower);
    4. Exhaust fan (S);
    5. Heat-resistant moulded part - nozzle;
    6. Control panel;
    7. Safety thermostat;
    8. Control valve;
    9. Heat-resistant moulded part, rtpe GD, side of the hearth;
    10. Heat-resistant shape - type GD - in spherical space;
    11. Sealer - nozzles - 12x12 (14x14);
    12. Heat-resistamt shape - crescent;
    13. Lightning valve;
    14. Heat-resistamt shape - type GD - rear face of spherical space;
    15. Cleaning cover;
    16. Frame cover;
    17. Heating valve pull;
    18. Thermometer;
    19. Supply air duct;
    20. On/Off switch with indicator;
    21. ----
    22. Thrust regulator - Honeywell FR 124;
    23. Cooling loop against overheating;
    24. Control fan thermostat (boiler);
    25. Door filling - Sibral;
    26. Door sealant - rope 18x18;
    27. Flue gas thermostat;
    28. ----
    29. ----
    30. Fan capacitor - 1μF;
    31. ----
    32. ----
    33. Pipe heat exchanger.

K - Conduit connection

L - Boiler water outlet

M - Boiler Water intel

N - Base of the filling tap

P - Connection for valve sensor to control the cooling spiral

Boiler dimensions Atmos Dokogen DC

Boiler Type
DC18GD DC25GD DC30GD DC40GD DC50GD
A 1281 1281 1281 1435 1435
B 820 1020 1020 1120 1120
C 680 680 680 680 680
D 945 945 945 1095 1095
E 150/152 150/152 150/152 150/152 150/152
F 87 87 87 82 78
G 185 185 185 185 185
H 1008 1008 1008 1152 1152
CH 256 256 256 256 256
I 256 256 256 256 256
J 6/4" 6/4" 6/4" 2" 2"

Technical data

Boiler Type
DC18GD DC25GD DC30GD DC40GD DC50GD
Boiler power
kW 19 25 29,5 40 49
Recomended chimney draught
Pa 16 18 20 22 24
Max pressure working water
kPa 250 250 250 250 250
Boiler weight
kg 376 469 466 548 565
Water volume in the boiler l 73 105 105 112 128
Fuel well capacity
dm3 85 125 125 170 170
Max length of wood
mm 330 530 530 530 530
Diameter of the exhaust pipe
mm 150/152 150/152 150/152 150/152 150/152
Effciency % 90,3 90,5 90,8 90,5 92
Exhaust gas temperature at rated power
°C 145 132 155 175 183
Required fuel (recomended)
Dry wood with a calorfic value of 15 - 18 MJ/kg, diameter 80 - 150 mm and humidity 12 - 20%
Minimum return flow temperature
°C 65
Boiler class
5
Energy effciency class
A+
EKODESIGN YES

Product Details

Brand
Reference
38721
Condition
New
Product type
Gasification boiler
EcoDesign
wood
YES
Class
5
Width [ mm ]
680
Max. operating pressure [ bar ]
2,5

Comments

4 other products in the same category

Viewed products

1000+

Produktów w ofercie

24h

Szybka dostawa

5/5

Wysoka jakość obsługi

5000+

Zadowolonych klientów

Loading...
Back to top