Reference: 12240

Wood Gasifier ATMOS DC GS is a gasification boiler using the wood gas generator principle (Holzgasgenerator). The large surface area of used boiler ceramics supports the pyrolysis gases afterburning. Usage of an exhaust fan provides dust-free boiler room. Cooling loop protects the gasifying boiler from overheating. Flue thermostat automatically turns off the boiler after the wood combustion.

Wood gasification boiler ATMOS DC GSX with extraction fan

Reference: 12240

Wood Gasifier ATMOS DC GS is a gasification boiler using the wood gas generator principle (Holzgasgenerator). The large surface area of used boiler ceramics supports the pyrolysis gases afterburning. Usage of an exhaust fan provides dust-free boiler room. Cooling loop protects the gasifying boiler from overheating. Flue thermostat automatically turns off the boiler after the wood combustion.

Price: GBP4,008.75
Model-/-Name
Bezpieczne płatności

Testowy opis płatności

Szybka dostawa

Kolejny testowy opsi

30 dniowe zwroty

Zwroty do 30 dniu bezpłatne

Kup teraz, a otrzymasz w Monday, 30 November!
  • Credit Agricole Bank
  • ING Lease now
Wood gasification boiler ATMOS DC GSX with extraction fan
Price: GBP4,008.75
Notify me of availability

Description

Wood gasification boiler ATMOS DC GSX with exhaust fan

ATMOS DC GSX boilers utilize the principles of pyrolysis and wood gasification generator and are designed to burn wood as only solid fuel. The boiler body is made of high-quality steel with a thickness of 3-8 mm. Wood gasification boiler ATMOS DC series type GS comprises a chamber intended to store seasoned wood, the lower part of the chamber comes with a ceramic molding with an elongate opening providing the flow of exhaust gases to the afterburn chamber underneath. The lower combustion and ash chamber has a semi-circular ceramic coating. ATMOS afterburn combustion chamber in which the pyrolysis gases gather below is also equipped with a ceramic chamber, which spherically surrounds the outer part of the chamber and improves the quality of combustion. In the rear part of the ATMOS DC GSX central heating boiler, an exhaust gasses duct is placed in which upper part an ignition valve is located (controlled by a firing safety valve pull rod at the front). The upper part of the exhaust flue duct is connected to an outlet to the chimney.

The boiler ATMOS has many advantages like the possibility of burning large pieces of wood. Higher productivity provides the fact that the primary and secondary air is first heated up by the high temperature before used in the combustion process. Ash removal is easy because of the large and high lower combustion. Service and cleaning of the boiler are very simple as no firetube of the heat exchanger were used. More efficient combustion is provided by the ceramic fitting of the upper and lower combustion chamber. Large storage capacity for wood of the upper chamber and plenty of space for ash in the lower one (in the case of wood ash removal only once a week). The boiler is small and weighs little (when compared to traditional boilers). An exhaust fan (pressure ventilator) which provides dust-free removal of ash and no smoke in the boiler room when loading wood.

Inbuild cooling loop circuit prevents the risk of overheating and damaging the boiler or the central heating installation. ATMOS DC GSX wood gasification boiler utilizes a thermostat that automatically switches off the boiler after the combustion of wood is completed.

When choosing a boiler with Laddomat or mixing valve and accumulation tank (buffer tank) as accessories the customer receives a 3-year warranty. Installing a boiler without heat accumulation and Laddomat or mixing valve the given warranty period is 2 years.

ATMOS DC GSX central heating boiler in order to achieve the minimum required temperature of the return water at 65 ° C, should be working with a charging unit pump Laddomat or a mixing valve. All boilers are supplied with cooling loop preventing overheating but it is recommended to work in a central heating installation with accumulation tank and Laddomat unit (found in accessories).

Boiler construction scheme of ATMOS DC GSX wood gasification boiler

Construction scheme of a wood gasification ATMOS DC GSX type

  1. Boiler drum
  2. Loading door
  3. Ash pan door
  4. Fan (pressure ventilator)
  5. Fireproof and heat-resisting fitting - nozzle
  6. Control panel
  7. Safety thermostat
  8. Regulating safety valve
  9. missing in GSX model type
  10. Fireproof and heat-resisting fitting - GS - round space L+P
  11. Sealing - nozzles
  12. Fireproof and heat-resisting fitting - half-moon
  13. Firing safety valve
  14. Fireproof and heat-resisting fitting - GS - rear face of round space
  15. Cleaning cover
  16. Orifice plate
  17. Firing safety valve pull rod
  18. Thermometer
  19. Furnace orifice plate
  20. Switch
  21. Power regulator - Honeywell FR124
  22. Cooling loop
  23. Fan thermostat
  24. V. Door panel - Sibrall
  25. Door sealing - cord 18 x 18
  26. Waste gas thermostat

ATMOS DC GSX wood gasification boiler dimensions

Dimensions of wood gasification boiler ATMOS DC GSX type

  DC
50 GSX
DC
70 GSX
A 1558 1648
B 1042 1068
C 678 678
D 997 1054
E 150 (152) 180
F 70 70
G 184 184
H 1287 1372
CH 256 256
I 256 256
J 2" 2"

Product Details

Brand
Reference
12240
Condition
New
ean13
8595183300808
Product type
Boiler
Gasification boiler
Steel boiler
Efficiency [ % ]
90
Width [ mm ]
678
Outlet and inlet supply size [ inch ]
2''
Min. working temperature [ °C ]
65
Ventilator
Extraction
YES
Mains voltage [ V ]
230
Fuel
wood
YES
Warranty
3 years for boiler installed with Laddomat and accumulation tank

Comments

4 other products in the same category

Viewed products

1000+

Produktów w ofercie

24h

Szybka dostawa

5/5

Wysoka jakość obsługi

5000+

Zadowolonych klientów

Loading...
Back to top