PROSAT WEBER X is a series of heat pumps designed for domestic hot water (DHW) production in residential buildings and small utility buildings. The units use energy contained in the air to heat the water stored in the tank.
Domestic Hot Water Heat Pump WEBER X
PROSAT WEBER X is a series of heat pumps designed for domestic hot water (DHW) production in residential buildings and small utility buildings. The units use energy contained in the air to heat the water stored in the tank.
- New
Description
PROSAT WEBER X – Domestic Hot Water Heat Pump with R290 Refrigerant
PROSAT WEBER X is a series of heat pumps designed for domestic hot water (DHW) production in residential buildings and small utility buildings. The units use energy contained in the air to heat the water stored in the tank.
The series includes models equipped with tanks with capacities of 100, 120, 150, 200 and 300 litres. Different tank capacities allow the unit to be selected according to the required domestic hot water storage capacity.
PROSAT WEBER X DHW Heat Pump with R290 Refrigerant
PROSAT WEBER X uses R290 (propane) as the refrigerant. According to the technical documentation, the factory refrigerant charge is 150 g. For R290, the documentation specifies a global warming potential (GWP) of approximately 1.
The primary purpose of the heat pump is domestic hot water production. The unit design also allows the air passing through the heat pump to be used for additional applications such as room cooling, air dehumidification and heat recovery. These functions are supplementary.
DHW Temperature Range
The water temperature in PROSAT WEBER X units can be set within the range of 15–75°C. The maximum water temperature specified in the documentation is 75°C.
The units are also equipped with a 1.6 kW auxiliary electric heater. The combination of heat pump operation and the electric heater enables hybrid operation.
PROSAT WEBER X Operating Modes
The controller allows the selection of various operating modes, including heat pump operation, operation using only the auxiliary electric heater, and hybrid operation combining the heat pump with the auxiliary heater.
- STAN – heat pump operating mode,
- HYB1 – heat pump operation with the auxiliary electric heater,
- ELE – operation using the auxiliary electric heater.
The controller is also equipped with a forced defrost function and a ventilation function. A sterilisation function using the heat pump and auxiliary electric heater is also available.
Automatic Sterilisation Function
PROSAT WEBER X is equipped with a tank sterilisation function. The user can enable or disable automatic sterilisation and set the frequency at which it is performed.
The default automatic sterilisation interval is 7 days, while the available setting range is from 1 to 20 days.
Wi-Fi Control and Smart Life Application
PROSAT WEBER X heat pumps are equipped with Wi-Fi connectivity, allowing the unit to be connected to the Smart Life application. Connection configuration can be performed using Smart Network or AP Network mode.
After connecting the unit to the application, the user can access the heat pump control interface and select the appropriate operating mode. The device can also be shared with another application user, and its name and location can be changed in the settings.
Timer and Operating Schedule
The PROSAT WEBER X controller enables the operating time of the unit to be programmed. Up to three time periods can be configured, with a start time and end time specified for each period.
The unit also features a clock and weekly scheduler, allowing the operating schedule to be adjusted to the planned domestic hot water usage.
Energy-Efficient Domestic Hot Water Production
PROSAT WEBER X uses energy contained in the air and transfers it to the water stored in the tank. According to the manufacturer's documentation, the solution is designed for DHW production while reducing electricity demand compared with direct water heating using an electric heater.
Depending on the model, the COP at 7/6°C ranges from 2.74 to 3.02. All models have an A+ energy efficiency class according to the data provided in the technical specification table.
Utilisation of Waste Heat Air
The design of the PROSAT WEBER X allows the unit to be installed in rooms where warm waste air is available. The documentation specifies, among others, utility rooms, boiler rooms, garages and other technical spaces.
The heat pump can simultaneously produce DHW and affect the temperature and humidity of the air in the room. Cooling, dehumidification and heat recovery are additional functions and cannot be controlled with the same precision as the primary water heating function.
Compact Design and Different Tank Capacities
The PROSAT WEBER X series includes models with tank capacities of 100, 120, 150, 200 and 300 litres. According to the documentation, the 100, 120 and 150 litre models are designed for wall-mounted installation, while the 200 and 300 litre versions are floor-standing models.
PROSAT WEBER X Technical Specification
| Parameter | WEBER X-100-1W | WEBER X-120-1W | WEBER X-150-1W | WEBER X-200-1W | WEBER X-300-1W |
|---|---|---|---|---|---|
| Tank capacity | 100 l | 120 l | 150 l | 200 l | 300 l |
| Nominal heating capacity | 1.1 kW | 1.1 kW | 1.1 kW | 1.6 kW | 1.6 kW |
| Heating capacity at 7/6°C | 0.80 kW | 0.82 kW | 0.84 kW | 1.302 kW | 1.18 kW |
| COP at 7/6°C | 2.74 | 2.81 | 2.87 | 2.97 | 3.02 |
| Energy efficiency class | A+ | A+ | A+ | A+ | A+ |
| Sound power level | 55 dB(A) | 55 dB(A) | 55 dB(A) | 55 dB(A) | 55 dB(A) |
| Power supply | 220–240 V / 1 / 50 Hz | 220–240 V / 1 / 50 Hz | 220–240 V / 1 / 50 Hz | 220–240 V / 1 / 50 Hz | 220–240 V / 1 / 50 Hz |
| Refrigerant | R290 | R290 | R290 | R290 | R290 |
| Refrigerant charge | 150 g | 150 g | 150 g | 150 g | 150 g |
| Airflow rate | 500 m³/h | 500 m³/h | 500 m³/h | 500 m³/h | 500 m³/h |
| Air duct diameter | 150 mm | 150 mm | 150 mm | 150 mm | 150 mm |
| Maximum water temperature | 75°C | 75°C | 75°C | 75°C | 75°C |
| Temperature setting range | 15–75°C | 15–75°C | 15–75°C | 15–75°C | 15–75°C |
| Tank material | Enamel | Enamel | Enamel | Enamel | Enamel |
| Net weight | 51 kg | 59 kg | 69 kg | 93 kg | 117 kg |
Unit Dimensions
| Model | Unit dimensions | Packaging dimensions |
|---|---|---|
| WEBER X-100-1W | Ø510 × 1240 mm | 570 × 570 × 1280 mm |
| WEBER X-120-1W | Ø510 × 1435 mm | 570 × 570 × 1595 mm |
| WEBER X-150-1W | Ø510 × 1660 mm | 570 × 570 × 1845 mm |
| WEBER X-200-1W | Ø570 × 1720 mm | 640 × 640 × 1890 mm |
| WEBER X-300-1W | Ø650 × 1926 mm | 720 × 720 × 2070 mm |
Equipment and Technical Features
- enamelled DHW tank,
- R290 refrigerant,
- 1.6 kW auxiliary electric heater,
- electronic expansion valve,
- Wi-Fi function,
- Smart Life application support,
- timer with up to three time periods,
- sterilisation function,
- hybrid mode – heat pump + electric heater,
- forced defrost function,
- ventilation function,
- water temperature setting range of 15–75°C.
Application of the PROSAT WEBER X Heat Pump
PROSAT WEBER X is primarily designed for domestic hot water production. According to the documentation, the unit can be used in residential buildings and small utility buildings.
Thanks to its air duct design, the unit can also be installed in rooms where warm waste air is available. Depending on the installation configuration, the heat pump can simultaneously affect the temperature and humidity of the air in the room.
Important Installation Information
Installation and all work related to the installation of the unit should be carried out by qualified personnel. The heat pump is designed for indoor installation and must not be installed outdoors or in locations exposed to rain.
During installation, sufficient clearance around the unit must be provided to ensure proper airflow and access for servicing. When air ducts are used, their combined total length for the inlet and outlet should not exceed 2 metres, in accordance with the unit's manual.
Due to the use of the flammable R290 refrigerant, any work requiring intervention in the refrigeration circuit should be carried out by personnel with the appropriate qualifications.
PROSAT WEBER X – DHW Heat Pump
PROSAT WEBER X combines a domestic hot water heat pump with an enamelled storage tank, an auxiliary electric heater, Wi-Fi control and operating schedule programming functions.
The series includes five tank capacity variants – 100, 120, 150, 200 and 300 litres. The use of R290 refrigerant, an A+ energy efficiency class, hybrid operation, automatic sterilisation and control via the Smart Life application are features of the PROSAT WEBER X series designed for domestic hot water production.
Frequently Asked Questions
Is the PROSAT WEBER X designed for space heating?
No. The unit is primarily designed for domestic hot water heating. Cooling, dehumidification and heat recovery from the air are supplementary functions.
Does the PROSAT WEBER X heat pump have Wi-Fi?
Yes. The unit features Wi-Fi connectivity and can be connected to the Smart Life application.
Which refrigerant is used in the PROSAT WEBER X?
The unit uses R290 (propane), and the documentation specifies a refrigerant charge of 150 g.
What DHW temperature can be set?
The temperature setting range is 15–75°C, while the maximum water temperature specified in the documentation is 75°C.
What tank capacities are available?
The series includes models with tank capacities of 100, 120, 150, 200 and 300 litres.
Comments
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent