The DROPS M4.1 air-to-water heat pump is designed for domestic hot water preparation using any type of storage tank. The tank can be connected directly to the secondary circuit of the heat pump with the domestic hot water circuit, or by using an additional coil or a water jacket.

The heat pump for DHW heating 2,5 kW DROPS M4.1

The DROPS M4.1 air-to-water heat pump is designed for domestic hot water preparation using any type of storage tank. The tank can be connected directly to the secondary circuit of the heat pump with the domestic hot water circuit, or by using an additional coil or a water jacket.

Price: GBP1,121.87
Bezpieczne płatności

Testowy opis płatności

Szybka dostawa

Kolejny testowy opsi

30 dniowe zwroty

Zwroty do 30 dniu bezpłatne

Kup teraz, a otrzymasz w Monday, 30 November!
  • Credit Agricole Bank
  • ING Lease now
The heat pump for DHW heating  2,5 kW DROPS M4.1
Price: GBP1,121.87
Notify me of availability

Description

DROPS Air-to-Water Heat Pump - Technical Description

DROPS Air-to-Water Heat Pump

The air-to-water heat pump is designed for heating domestic hot water (DHW). The rotary compressor used has been optimized for condensation at high temperatures, meaning high DHW temperatures. Airflow through the heat exchanger is forced by an energy-efficient, high-performance, and modern EBM PAPST fan. Water heating takes place in a stainless steel plate heat exchanger, and water circulation is provided by a Wilo circulation pump – also suitable for potable water operation. The entire system is controlled by a controller equipped with an algorithm optimized for the design and operation of the heat pump. The housing is made of ABS plastic.

Pump components
Air inlet and outlet
  1. Air outlet
  2. Air inlet
  3. Hot water outlet
  4. Cold water inlet
  5. Control panel
  6. Air outlet
  7. Air inlet

AIR DRAWN FROM ONE ROOM AND EXHAUSTED INTO ANOTHER ROOM

Diagram No. 1

AIR DRAWN FROM A ROOM AND EXHAUSTED OUTSIDE THROUGH A WALL

Diagram No. 2

AIR DRAWN FROM OUTSIDE THROUGH A WALL AND EXHAUSTED OUTSIDE THROUGH A WALL

Diagram No. 3

AIR DRAWN FROM OUTSIDE THROUGH A WALL AND EXHAUSTED OUTSIDE THROUGH THE ROOF

Diagram No. 4

SEPARATION OF SUPPLY AND EXHAUST AIR

Diagram No. 5

HEAT PUMP OPERATING WITH A HEAT RECOVERY UNIT

Diagram No. 6

The heat pump and the heat recovery unit operate independently, so the ventilation ducts should also be separated. This ensures that when the heat recovery unit is running but the heat pump is not, air flows freely to the ventilation exhaust and not into the heat pump. Otherwise, it would reduce the efficiency of the heat recovery unit’s fan.

Application range Inlet air temperature: 20°C Inlet air temperature: 35°C
Outdoor temperature min/max [°C] +5 / +43 +5 / +43
Maximum DHW temperature with heat pump °C 60 60
DHW temperature with electric heater °C 75 75
Minimum installation area m² 1 1
Heat transfer medium - Water Water
Electrical parameters
Electrical supply - 1/N/PE 220-240V/50Hz 1/N/PE 220-240V/50Hz
Recommended fuse A C6 C6
Max. start-up current of heat pump A 15.2 15.2
Max. operating current of heat pump A 3 3
Fan / pump power consumption W 90 / max 55 90 / max 55
Power consumption for inlet air temperature: min 0.29 kW, max 0.560 kW min 0.29 kW, max 0.650 kW
Maximum heating capacity for inlet air temperature 1.98 kW 2.57 kW
Average heating capacity for inlet air temperature and DHW heating 10-60°C: 1.49 kW 1.9 kW
COP, water heating 10 ÷ 40°C: 4.33 6.9
COP, water heating 10 ÷ 45°C: 3.98 6.6
COP, water heating 10 ÷ 50°C: 3.55 5.7
COP, water heating 10 ÷ 55°C: 3.22 4.9
Heating time for 100 L water 10 ÷ 40°C: 2h:30min 1h:30min
Heating time for 100 L water 10 ÷ 45°C: 3h:12min 1h:54min
Heating time for 100 L water 10 ÷ 50°C: 4h:00min 2h:36min
Heating time for 100 L water 10 ÷ 55°C: 4h:42min 3h:24min

The above COP values and heating times were determined under the following conditions: inlet air temperature 20°C / 35°C. Pump connected directly to the water tank. Air drawn directly from the room. In different conditions, the values given above may change.

Buffer diagram
Coil diagram
Water jacket diagram
Refrigeration circuit
Compressor type rotary
Compressor oil type ATMOS-RB68EP/FVC68D Quantity: 320 ml ±20
Refrigerant / quantity type / kg R134a / 0.6 kg
Max. allowable pressure (low pressure) bar 7
Max. allowable pressure (high pressure) bar 23
Dimensions
Diameter Ø mm 661
Height mm 563
Weight kg 45
Heating circuit parameters
Heating circuit connection fittings inch 2xGW 3/4"
Minimum internal pipe diameter mm 20
Flow rate m³/h 0.280
Working medium - water / propylene glycol

Direct to DHW
The installed WILO pump allows direct connection of the DROPS heat pump to the domestic hot water installation.

Product Details

Condition
New
Product type
heat pump
Class
A
Weight [ kg ]
45
Height [ mm ]
563
Exhaust gas pipe size [ mm ]
200
Diameter [ mm ]
661
Outlet and inlet supply size [ inch ]
3⁄4''
Installation
Floor
Horizantal
Internal
Steering
CUW pump
YES
Mains voltage [ V ]
230
Warranty
2 years
Colour
White

Comments

4 other products in the same category

1000+

Produktów w ofercie

24h

Szybka dostawa

5/5

Wysoka jakość obsługi

5000+

Zadowolonych klientów

Loading...
Back to top